Protection for the water heater
Instruction Manual DR-FC
13
gis
2.4.1
Water temperature protection
With temperature sensor T
, the control panel
monitors three temperatures which are important for safety.
explains
the functioning of the temperature sensors.
2.4.2
Gas control
The control panel opens the gas control so that gas can be supplied to the
burner. As a safety measure, the gas control has two valves. Both valves shut
off the gas supply.
Smooth ignition is achieved by opening the gas control with a delay (‘softlite’).
2.4.3
Fan
The fan provides an optimum air supply when there is a heat demand. A safety
aspect is that the fan ensures that any gases present in the combustion
chamber get removed, both before and after combustion. We refer to this as
pre- and post-purge.
The fan speed is continuously monitored by the control panel. The control panel
takes control if the speed of rotation varies too much from the value set.
2.4.4
Pressure switch
The pressure switch ensures the discharge of flue gases and the supply of
incoming air during the pre-purge and normal running of the water heater. The
standard position of the pressure switch is open. When sufficient pressure
differential is reached, the pressure switch closes. However, in the event of a
fault, the pressure switch will be tripped open, and the heating cycle will be
interrupted.
Tabel 2.1
Temperature protection
Protection
Description
Against frost
(T
1
< 5°C or T
2
< 5°C)
The frost protection cuts in. The water is heated to 20°C.
For maximum water temperature
(T
1
> 85°C or T
2
> 85°C)
The high-limit safeguard serves to prevent overheating and/or excessive
formation of scale in the water heater. Should the high-limit safeguard be
activated, the heating is halted. This causes the water in the heater to cool
down. Once the water has cooled sufficiently (T
1
< 78 °C), the control panel
resets the water heater.
For extra safety
(T
1
> 93°C or T
2
> 93°C)
A lockout error of the water heater controller takes place. The controller must
be manually reset before the water heater can resume operation (see
paragraph
). The reset may only be performed once T
1
<
78°C.
Содержание DR-FC 25
Страница 2: ...2...
Страница 6: ...6 Instruction Manual DR FC gis A Appendices 95 A 1 Introduction 95 A 2 Electrical diagram DR FC 96...
Страница 16: ...Functioning of the water heater 16 Instruction Manual DR FC 2 gis...
Страница 42: ...Filling and draining 42 Instruction Manual DR FC 4 gis...
Страница 46: ...The control panel 46 Instruction Manual DR FC 5 gis...
Страница 50: ...Status of the water heater 50 Instruction Manual DR FC 6 gis...
Страница 56: ...Starting up and shutting down 56 Instruction Manual DR FC 7 gis...
Страница 68: ...Main menu 68 Instruction Manual DR FC 8 gis...
Страница 72: ...Service program 72 Instruction Manual DR FC 9 is...
Страница 88: ...Troubleshooting 88 Instruction Manual DR FC 10 gis...
Страница 90: ...Maintenance frequency 90 Instruction Manual DR FC 11 gs...
Страница 98: ...Appendices 98 Instruction Manual DR FC A is...