14
PUMA 480LM
P48LMISE98
5. Connecting the main power and air sources
5.1 Connecting the main power source
※
Power Consumption
Item
Puma480LM
Power Voltage
380/440 V, 50/60Hz
200/220 V, 50/60 Hz
Cable Thickness
25mm²
70mm²
Allowable Voltage
Variation
10%
Apparent Power
58.1 KVA
The machine may not operate properly if supplied with insufficient power, even causing
a risk of physical damage. So make sure to keep the proper supply of power by
employing necessary devices.
※
Checking the main power connection
Before operating the machine, check the pressure setting of the hydraulic tank to ensure
that the power cable is connected properly. After the main power is connected, be sure
to check if the pressure of the gauge is set to 40 bars as shown.
1) Connect the earth wire to the PE(Protective Earth) terminal of the electric cabinet.
2) Do not make the power cable and the earth wire in serial connection. Otherwise, this
may cause a negative electrical impact on other connected devices or a failure of the
circuit breaker.
Warning
Caution