DOOSAN INFRACORE 25/36
25
20
CC-Link Unit-1 Fault
-CC-Link of Stacker Crane is not ready.
Check CC-Link 1 cable and connector.
Check if CC-Link board is broken , and if it is so,
replace them
21
CC-Link Unit-2 Fault
-CC-Link of Setup station #1 is not ready.
Check CC-Link of Setup station #1 cable and
connector.
Check if CC-Link is broken , and if it is so, replace
them
22
CC-Link Unit-3 Fault
- CC-Link of Setup station #2 is not ready.
Check CC-Link of Setup station #2 cable and
connector.
Check if CC-Link is broken , and if it is so, replace
them
23
MC1 DP Fault
- When Machining Center #1 is turned off or
DP cable is troubled, this alarm is occurred.
-Turn on the power of the Machining Center
- Check DP cable and connector.
- Check if DP board is broken , and if it is so,
replace them
24
MC2 DP Fault
- When Machining Center #2 is turned off or
DP cable is troubled, this alarm is occurred.
-Turn on the power of the Machining Center
- Check DP cable and connector.
- Check if DP board is broken, and if it is so,
replace them.
25
MC3 DP Fault
- When Machining Center #3 is turned off or
DP cable is troubled, this alarm is occurred.
-Turn on the power of the Machining Center # 3
- Check DP cable and connector.
- Check if DP board is broken , and if it is so,
replace
26
System PC Communication Fault
- When PLC is turned off or Ether net cable is
troubled, this alarm is occurred.
-Turn on the PLC
- Check cable and connector.
- Check if Ethernet cable is broken , and if it is so,
replace
30
Left Safety Door Open
- When Left door is opened, this alarm is
occurred.
- Check the status of left door, and close left door
completely.
31
Right Safety Door Open
- When Right door is opened, this alarm is
occurred.
- Check the status of Right door and close the Right
door completely.
33
Setup ST.-1 Door Close or Open Fault
- When [Setup ST.-1] door isn t opened or
closed completely for 7 seconds, this alarm is
occurred
- Check the status of the [Setup ST.-1] door and
open or close the setup door completely.
36
Setup ST.-2 Door Close or Open Fault
- When Setup ST.-2 door isn t opened or
closed completely for 7 seconds, this alarm is
occurred
- Check the Setup ST.-2 door and open or close the
door completely.
40
X-Axis + Over Trouble
- X-axis goes beyond the upper limits of
numeric values setting in parameter,
- move X-Axis within the upper limits of X-axis.
41
X-Axis - Over Trouble
- X-axis goes beyond the lower limits of
- move X-Axis within the lower limits of X-axis