DOOSAN INFRACORE 24/36
24
8.
着报警故障措施要点
8.1 Alarm
报警
Code
Descriptions/cause
Troubleshooting
2
Servo Control Power Break Trip
- When power is not supplied to servo motor,
this alarm is occurred.
Check if control power switch (2.4.3) on front of
control panel is on.
3
AC220V Control Power Break Trip
- When over current flows into 220 volt line
system of the main panel, this alarm is
occurred.
Check if cable or connector are short-circuited, and
if it is so, replace them.
Check if control power breaker is broken, and if it
is so, replace them.
- replace appropriate breaker specification
4
DC24V Control Power Break Trip
- When over current flows into 24 volt line
system of the main panel, this alarm is
occurred.
- Inappropriate breaker specification
- Check if cable or connector are short-circuited,
and if it is so, replace them.
- Check if control power breaker is broken, and if it
is so, replace them.
- replace appropriate breaker specification
5
System PC Power Break Trip
- When over current flows into pc power line
system in the main panel, this alarm is
occurred.
- Inappropriate CONTACTOR MAGNET
specification
- Check if cable or connector are short-circuited,
and if it is so, replace them.
- Check if CONTACTOR MAGNET is broken,
and if it is so, replace them.
- replace to the appropriate Contactor Magnet
Switch specification.
10
Emergency Stop
-When [2.3.1] or [2.4.1] emergence button is
pressed, this alarm is occurred.
- Turn Off the Emergency Stop Button on [2.3.1]
or [2.4.1] and reset the LPS controller
11
MC1 Emergency Stop
-When operator press emergence stop button of
MC1, this alarm is occurred.
- Turn OFF the Emergency Stop Button of MC1 and
reset the LPS controller.
12
MC2 Emergency Stop
-When operator press emergence stop button of
MC2, this alarm is occurred.
- Turn OFF the Emergency Stop Button of MC2 and
reset LPS controller.
13
MC3 Emergency Stop
-When operator press emergence stop button of
MC3 this alarm is occurred.
- Turn OFF the Emergency Stop Button of MC3and
reset LPS controller.
15
X-Axis Error (QD75M4)
- trouble with X axis
Refer to Mitsubish Melservo J3s Instruction
Manual
16
Y-Axis Error (QD75M4)
- trouble with Y axis
Refer to Mitsubish Melservo J3s Instruction
Manual
17
Z-Axis Error (QD75M4)
- trouble with Z axis
Refer to Mitsubish Melservo J3s Instruction
Manual