Disassembly and Reassembly of Major Components
- 107 -
3.6.5. Ignition state checks
1) The last setup screen permits the operator to enter an ignition test mode. This test mode can fire all
outputs in rotation, or individual outputs at a slow rate. This feature can be used to troubleshoot pri-
mary wiring and operation. Test mode will terminate if rotation of the engine is sensed. Diagnostic
features do not function while in test mode.
Caution:
the operator must fully purge the engine of combustible mixtures prior to selecting the test
mode operation. Pressing the enter key again is a confirmation of this action.
2) Then the test mode screen indicates that the ignition is firing and permits the operator to select the
output to be fired.
EGV2218027
RUN
TEST
MODE
Next
Esc
Enter
ENTER
NEXT
ESC
Press to exit
Press for test mode
Press for next option
EGV2218028
IS
ENGINE
PURGED
Esc
Enter
ENTER
ESC
Press to exit
Press to verify purged
Then before starting test mode
EGV2218029
TEST - Mode ALL
Esc
ESC
Press to exit
Press to select
Previous output
Press to select
Next output
Содержание GV158TIC