G424F(FE) Service Manual
Chapter 3. Engine Mechanical System
66
Make proper antifreeze additions.
Adding pure antifreeze as a makeup solution for
cooling system top-up is an unacceptable practice. It
increases the concentration of antifreeze in the
cooling system which increases the concentration of
dissolved solids and undissolved chemical inhibitors
in the cooling system. Add antifreeze mixed with
water to the same freeze protection as your cooling
system.
Thermostat Housing
Components
1) Seal 2) Housing 3) Sensor 4) Bolt 5) Seal
6) Thermostat 7) Bolt 8) Inlet-Water 9) Stud
Removal
Remove or disconnect
1.
Battery negative cable.
2.
Drain the coolant, loosening the radiator lower
hose.
3.
Electric connection from the temperature sensor.
4.
Radiator-to-thermostat upper hose, with a 6-mm
socket wrench and handle.
5.
Timing belt rear cover; see “Timing Belt Rear
Cover – Removal”, in this section.
6.
With special clamp pliers, loosen the upper hose
from the cab heating pipe, below the intake
manifold.
7.
Thermostat housing-to-cylinder head attaching
bolts, with a 13-mm socket and handle.
8.
Pull out the thermostat housing and remove the
lower hose to the thermostat housing, with a 10-
mm socket wrench and handle.
9.
Thermostat housing.
Installation
Install or connect
1.
A new “O” ring in the thermostat housing to the
cylinder head.
2.
Lower hose to the thermostat housing and clamps.
3.
Use a 10-mm socket wrench and torque wrench
to tighten the clamp.
Tighten
•
Clamp: 4 – 5 N
·
m (3 – 3,6 lb
·
ft).
4.
Thermostat housing and attaching bolts; without
tightening.
Obs.:
When installing the thermostat housing, the
heater pipe upper hose should be placed below the
manifold.
5.
With a 13-mm socket wrench and torque wrench;
tighten the attaching bolts.
Tighten
•
10 – 20 N
·
m (7 – 15 lb
·
ft.).
6.
Using special clamp pliers, install the upper hose
clamp below the intake manifold.
7.
Timing belt rear cover; see “Timing Belt -
Installation”, in this section.
8.
Radiator-to-thermostat upper hose and clamp.
9.
With a 6-mm socket wrench and torque wrench;
tighten the clamp.
Tighten
•
Bolts: 4 – 5 N
·
m (3 – 3,6 lb
·
ft.).
10.
Temperature sensor electric connection.
11.
Refill the cooling system.
12.
Battery negative cable.
Содержание G20P-5
Страница 2: ......
Страница 4: ......
Страница 31: ...G424F FE Service Manual Chapter 2 Recommended Maintenance 29 ...
Страница 36: ...G424F FE Service Manual Chapter 3 Engine Mechanical System 34 MAIN BEARINGS 0 50 UNDERSIZE ...
Страница 86: ...G424F FE Service Manual Chapter 3 Engine Mechanical System 84 ...
Страница 113: ...G424F FE Service Manual Chapter 4 Engine Electrical System 111 2 Alternator and outer terminal connection inspection ...
Страница 153: ...G424F FE Service Manual Chapter 5 Engine Management System EMS 151 Figure 22 SECM Wiring Diagram for G424FE LP System ...
Страница 162: ...G424F FE Service Manual Chapter 5 Engine Management System EMS 160 SECM Wiring Diagrams for G424F LP Engine ...
Страница 230: ...G424F FE Service Manual 228 Chapter 8 Basic Troubleshooting Irregular Idling Or Engine Is Suddenly Stopped ...
Страница 231: ...G424F FE Service Manual 229 Chapter 8 Basic Troubleshooting Engine Hesitation Or Insuffient Accelelation ...
Страница 232: ...G424F FE Service Manual 230 Chapter 8 Basic Troubleshooting ...
Страница 234: ...G424F FE Service Manual 232 Chapter 8 Basic Troubleshooting ...