G424F(FE) Service Manual
Chapter 9. Advanced Diagnostics
258
Table 1. Fault List Definitions (cont’d.)
FAULT DESCRIPTION
CODE
(MI04 CODE)
LiqPostO2Inactive
Post-catalyst O2 sensor control on gasoline has sensed the
O2 sensor is not responding as expected. If any Pre-O2
sensor faults are set, diagnose these first and after correcting
these faults recheck if this fault sets. Possible causes for this
fault are sensor disconnected, sensor heater failed, sensor
element failed, heater relay, or SECM control of heater relay
is disconnected or failed.
842
Reserved
843
LowOilPressureFault
Low engine oil pressure
521
(52)
MAPRangeHigh
Manifold Absolute Pressure Sensor Input is High, normally set
if the TMAP pressure signal wire has become shorted to
power, shorted to the IAT signal, the TMAP has failed or the
SECM has failed.
342
MAPRangeLow
Manifold Absolute Pressure Sensor Input is Low, normally set
if the TMAP pressure signal wire has been disconnected or
shorted to ground or the circuit has opened to the SECM
332
MAPTimeRangeHigh
Manifold Absolute Pressure Sensor Input is High, normally set
if the TMAP pressure signal wire has become shorted to
power, shorted to the IAT signal, the TMAP has failed or the
SECM has failed
341
(34)
MAPTimeRangeLow
Manifold Absolute Pressure Sensor Input is Low, normally set
if the TMAP pressure signal wire has been disconnected or
shorted to ground or the circuit has opened to the SECM
331
(33)
MAP_IR_HI
MAP sensor indicates higher pressure than expected
351
MAP_IR_LO
MAP sensor indicates lower pressure than expected
352
MAP_STICKING
MAP sensor not changing as expected
353
MediumOverspeed
Engine speed has exceeded the second level (2 of 3) of
overspeed protection
572
O2RangeHigh
Pre -catalyst O2 sensor voltage out of range high, sensor
signal shorted to power
921
O2RangeLow
Pre-catalyst O2 sensor voltage out of range low, sensor signal
shorted to ground
911
O2_PostCatRangeHigh
Post-catalyst O2 sensor voltage out of range high, sensor
signal shorted to voltage source (5V or battery)
922
O2_PostCatRangeLow
Post -catalyst O2 sensor voltage out of range low, sensor
signal shorted to ground
912
SensVoltRangeHigh
Sensor reference voltage XDRP too high
561
(56)
Содержание G20P-5
Страница 2: ......
Страница 4: ......
Страница 31: ...G424F FE Service Manual Chapter 2 Recommended Maintenance 29 ...
Страница 36: ...G424F FE Service Manual Chapter 3 Engine Mechanical System 34 MAIN BEARINGS 0 50 UNDERSIZE ...
Страница 86: ...G424F FE Service Manual Chapter 3 Engine Mechanical System 84 ...
Страница 113: ...G424F FE Service Manual Chapter 4 Engine Electrical System 111 2 Alternator and outer terminal connection inspection ...
Страница 153: ...G424F FE Service Manual Chapter 5 Engine Management System EMS 151 Figure 22 SECM Wiring Diagram for G424FE LP System ...
Страница 162: ...G424F FE Service Manual Chapter 5 Engine Management System EMS 160 SECM Wiring Diagrams for G424F LP Engine ...
Страница 230: ...G424F FE Service Manual 228 Chapter 8 Basic Troubleshooting Irregular Idling Or Engine Is Suddenly Stopped ...
Страница 231: ...G424F FE Service Manual 229 Chapter 8 Basic Troubleshooting Engine Hesitation Or Insuffient Accelelation ...
Страница 232: ...G424F FE Service Manual 230 Chapter 8 Basic Troubleshooting ...
Страница 234: ...G424F FE Service Manual 232 Chapter 8 Basic Troubleshooting ...