![Doosan G20P-5 Скачать руководство пользователя страница 267](http://html1.mh-extra.com/html/doosan/g20p-5/g20p-5_service-manual_2521425267.webp)
G424F(FE) Service Manual
Chapter 9. Advanced Diagnostics
265
Table 2. Diagnostic Fault Codes (Flash Codes) cont’d.
DFC PROBABLE
FAULT
FAULT
ACTION *
CORRECTIVE ACTION
FIRST CHECK
341
(34)
MAPTimeRangeHigh
Manifold Absolute Pressure
Sensor Input is High,
normally set if the TMAP
pressure signal wire has
become shorted to power,
shorted to the IAT signal, the
TMAP has failed or the
SECM has failed.
None
Check TMAP connector and MAP
signal wiring for a shorted circuit
TMAP Pin 4 to SECM Pin B18 (signal)
TMAP Pin 1 to SECM Pin B1 (sensor
GND)
TMAP Pin 3 to SECM Pin B24 (XDRP
+5 Vdc) Check the MAP sensor by
disconnecting the TMAP connector and
measuring at the sensor:
TMAP Pin 1(GND) to Pin 4 (pressure
signal KPA) (2.4k
Ω
- 8.2k
Ω
)
TMAP Pin 3 (power) to Pin 4 (pressure
signal KPA) (3.4k
Ω
- 8.2k
Ω
)
342
MAPRangeHigh
Manifold Absolute Pressure
Sensor Input is High,
normally set if the TMAP
pressure signal wire has
become shorted to power,
shorted to the IAT signal, the
TMAP has failed or the
SECM has failed
(1) TurnOnMil
(2) CutThrottle
Check TMAP connector and MAP
signal wiring for a shorted circuit
TMAP Pin 4 to SECM Pin B18 (signal)
TMAP Pin 1 to SECM Pin B1 (sensor
GND)
TMAP Pin 3 to SECM Pin B24 (XDRP
+5 Vdc)
Check the MAP sensor by
disconnecting the TMAP connector and
measuring at the sensor:
TMAP Pin 1(GND) to Pin 4 (pressure
signal KPA) (2.4k
Ω
- 8.2k
Ω
)
TMAP Pin 3 (power) to Pin 4 (pressure
signal KPA) (3.4k
Ω
- 8.2k
Ω
)
351
MAP_IR_HI
MAP sensor indicates higher
pressure than expected
None
Check for vacuum leaks. Check that
TMAP sensor is mounted properly.
Possible defective TMAP sensor.
352
MAP_IR_LO
MAP sensor indicates lower
pressure than expected
None
Possible defective TMAP sensor.
353
MAP_STICKING
MAP sensor not changing as
expected
None
Check that TMAP sensor is mounted
properly. Possible defective TMAP
sensor.
371
(37)
IATRangeLow
Intake Air Temperature
Sensor Input is Low normally
set if the IAT temperature
sensor wire has shorted to
chassis ground or the sensor
has failed.
TurnOnMil
Check TMAP connector and IAT signal
wiring for a shorted circuit
TMAP Pin 2 to SECM Pin B12 (signal)
TMAP Pin 1 to SECM Pin B1 (sensor
GND)
To check the IAT sensor of the TMAP
disconnect the TMAP connector and
measure the IAT resistance
Resistance is approx 2400 ohms at
room temperature.
(*) Fault actions shown are default values specified by the OEM.
Содержание G20P-5
Страница 2: ......
Страница 4: ......
Страница 31: ...G424F FE Service Manual Chapter 2 Recommended Maintenance 29 ...
Страница 36: ...G424F FE Service Manual Chapter 3 Engine Mechanical System 34 MAIN BEARINGS 0 50 UNDERSIZE ...
Страница 86: ...G424F FE Service Manual Chapter 3 Engine Mechanical System 84 ...
Страница 113: ...G424F FE Service Manual Chapter 4 Engine Electrical System 111 2 Alternator and outer terminal connection inspection ...
Страница 153: ...G424F FE Service Manual Chapter 5 Engine Management System EMS 151 Figure 22 SECM Wiring Diagram for G424FE LP System ...
Страница 162: ...G424F FE Service Manual Chapter 5 Engine Management System EMS 160 SECM Wiring Diagrams for G424F LP Engine ...
Страница 230: ...G424F FE Service Manual 228 Chapter 8 Basic Troubleshooting Irregular Idling Or Engine Is Suddenly Stopped ...
Страница 231: ...G424F FE Service Manual 229 Chapter 8 Basic Troubleshooting Engine Hesitation Or Insuffient Accelelation ...
Страница 232: ...G424F FE Service Manual 230 Chapter 8 Basic Troubleshooting ...
Страница 234: ...G424F FE Service Manual 232 Chapter 8 Basic Troubleshooting ...