G424F(FE) Service Manual
Chapter 6. LPG FUEL DELIVERY SYSTEM
185
CAUTION
•
LP gas is highly flammable. To prevent
personal injury, keep fire and flammable
materials away from the lift truck when work is
done on the fuel system.
•
Gas vapor may reduce oxygen available for
breathing, cause headache, nausea, dizziness
and unconsciousness and lead to injury or
death. Always operate the forklift in a well
ventilated area
Liquid propane may cause freezing of tissue or
frostbite. Avoid direct contact with skin or
tissue; always wear appropriate safety
protection including gloves and safety glasses
when working with liquid propane.
AVV (Air Valve Vacuum) Testing
Purpose of Test
Check for excessive or inadequate pressure drop
across CA100 mixer.
AVV Test Hardware
1.
Union Tee fitting, 1/4” (6.35mm) NPT with three
1/4” (6.35mm) NPT x 1/4” (6.35mm) hose barbs
2.
Vacuum hose
3.
0-20” H2O differential pressure Magnehelic gauge
AVV Test
1.
Install Union Tee fitting in the hose between the
FTVs and the AVV fitting. Connect this fitting to
the low pressure port of the Magnehelic gauge
(Figure 37).
2.
Leave high pressure port of the Magnehelic
gauge exposed to ambient pressure (Figure 37).
3.
With the engine fully warmed up and running at
idle (750 rpm) place the transmission in Neutral.
The AVV should be between 5” and 8” H2O of
pressure vacuum.
4.
If the measured pressure drop is excessively high,
check for sticking or binding of the diaphragm air
valve assembly inside the mixer. Replace mixer if
necessary.
5.
If the measured pressure drop is low, check for
vacuum leaks in the manifold, throttle, mixer,
TMAP sensor and attached hoses.
Figure 37. Magnehelic Gauge Connection
Ignition Timing Adjustment
With the MI-07 system, ignition-timing advance is
controlled by the SECM.
Connection of the MI-07 Service Tool
To use the Service Tool, a USB (Universal Serial
Bus) to CAN (Controller Area Network)
communication adapter by KVaser will be required
along with a Crypt Token (Figure 38). The Crypt
Token acts as a security key allowing the laptop to
retrieve the necessary data from the SECM.
1.
Install the Crypt Token in an available USB port in
the computer (Figure 39).
2.
With the ignition key in the OFF position, connect
the KVaser communication cable from a second
USB port on the computer to the CAN
communications cable on the engine. (*If your
laptop computer does not have a second USB
port an appropriate USB hub will need to be used).
3.
Connect a timing light to the engine.
4.
Turn the ignition key to the ON position (Do Not
Start the Engine).
5.
Launch the MotoView program on your computer
and open the Service Tool display (Figure 40).
Содержание G20P-5
Страница 2: ......
Страница 4: ......
Страница 31: ...G424F FE Service Manual Chapter 2 Recommended Maintenance 29 ...
Страница 36: ...G424F FE Service Manual Chapter 3 Engine Mechanical System 34 MAIN BEARINGS 0 50 UNDERSIZE ...
Страница 86: ...G424F FE Service Manual Chapter 3 Engine Mechanical System 84 ...
Страница 113: ...G424F FE Service Manual Chapter 4 Engine Electrical System 111 2 Alternator and outer terminal connection inspection ...
Страница 153: ...G424F FE Service Manual Chapter 5 Engine Management System EMS 151 Figure 22 SECM Wiring Diagram for G424FE LP System ...
Страница 162: ...G424F FE Service Manual Chapter 5 Engine Management System EMS 160 SECM Wiring Diagrams for G424F LP Engine ...
Страница 230: ...G424F FE Service Manual 228 Chapter 8 Basic Troubleshooting Irregular Idling Or Engine Is Suddenly Stopped ...
Страница 231: ...G424F FE Service Manual 229 Chapter 8 Basic Troubleshooting Engine Hesitation Or Insuffient Accelelation ...
Страница 232: ...G424F FE Service Manual 230 Chapter 8 Basic Troubleshooting ...
Страница 234: ...G424F FE Service Manual 232 Chapter 8 Basic Troubleshooting ...