OPERATING INSTRUCTIONS
31
7/125 - 9/115, 7/125 - 10/110, 14/90
J1939
SPN
J1939
FMI
CUMMINS
CODE
J1939 SPN DESCRIPTION
J1939 FMI DESCRIPTION
CUMMINS DESCRIPTION
3245
16
1972
Aftertreatment 1 Exhaust Gas
Temperature 3
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Aftertreatment Exhaust Gas Temperature 3 -
Data Valid But Above Normal Operating Range
- Moderately Severe Level
3246
0
3312
Aftertreatment 1 Diesel
Particulate Filter Outlet Gas
Temperature
Data Valid but Above Normal
Operational Range - Most
Severe Level
Aftertreatment Diesel Particulate Filter Outlet
Gas Temperature - Data valid but above
normal operational range - Most Severe Level
3249
2
1676
Aftertreatment 1 Exhaust Gas
Temperature 2
Data Erratic, Intermittent or
Incorrect
Aftertreatment Exhaust Gas Temperature 2 -
Data erratic, intermittent or incorrect
3249
3
1675
Aftertreatment 1 Exhaust Gas
Temperature 2
Voltage Above Normal, or
Shorted to High Source
Aftertreatment Exhaust Gas Temperature 2
Circuit - Voltage Below Normal, or Shorted to
Low Source
3249
4
1674
Aftertreatment 1 Exhaust Gas
Temperature 2
Voltage Below Normal, or
Shorted to Low Source
Aftertreatment Exhaust Gas Temperature 2
Circuit - Voltage Below Normal, or Shorted to
Low Source
3249
16
1968
Aftertreatment 1 Exhaust Gas
Temperature 2
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Aftertreatment Exhaust Gas Temperature 2 -
Data Valid But Above Normal Operating Range
- Moderately Severe Level
3249
17
2742
Aftertreatment 1 Exhaust Gas
Temperature 2
Data Valid but Below Normal
Operating Range Least
Severe Level
Aftertreatment Exhaust Gas Temperature 2 -
Data Valid But Below Normal Operating Range
- Least Severe Level
3249
18
2743
Aftertreatment 1 Exhaust Gas
Temperature 2
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Aftertreatment Exhaust Gas Temperature 2 -
Data Valid But Below Normal Operating Range
- Moderately Severe Level
3251
0
1922
Aftertreatment 1 Diesel
Particulate Filter Differential
Pressure
Data Valid but Above Normal
Operational Range - Most
Severe Level
Aftertreatment Particulate Filter Differential
Pressure - Data Valid But Above Normal
Operational Range - Most Severe Level
3251
2
1883
Aftertreatment 1 Diesel
Particulate Filter Differential
Pressure
Data Erratic, Intermittent or
Incorrect
Aftertreatment Particulate Filter Differential
Pressure Sensor - Data Erratic, Intermittent or
Incorrect
3251
3
1879
Aftertreatment 1 Diesel
Particulate Filter Differential
Pressure
Voltage Above Normal, or
Shorted to High Source
Aftertreatment Particulate Filter Differential
Pressure Sensor Circuit - Voltage Above
Normal, or Shorted to High Source
3251
4
1881
Aftertreatment 1 Diesel
Particulate Filter Differential
Pressure
Voltage Below Normal, or
Shorted to Low Source
Aftertreatment Particulate Filter Differential
Pressure Sensor Circuit - Voltage Below
Normal, or Shorted to Low Source
3251
15
2639
Aftertreatment 1 Diesel
Particulate Filter Differential
Pressure
Data Valid but Above Normal
Operating Range - Least
Severe Level
Aftertreatment Particulate Filter Differential
Pressure - Data Valid But Above Normal
Operating Range - Least Severe Level
3251
16
1921
Aftertreatment 1 Diesel
Particulate Filter Differential
Pressure
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Aftertreatment Particulate Filter Differential
Pressure - Data Valid But Above Normal
Operating Range - Moderately Severe Level
3481
16
2778
Aftertreatment 1 Fuel Rate
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Aftertreatment Fuel Rate - Data Valid But
Above Normal Operating Range - Moderately
Severe Level
3509
3
386
Sensor supply voltage 1
Voltage Above Normal, or
Shorted to High Source
Sensor Supply Voltage #1 Circuit - Voltage
Above Normal, or Shorted to High Source
3509
4
352
Sensor supply voltage 1
Voltage Below Normal, or
Shorted to Low Source
Sensor Supply Voltage #1 Circuit - Voltage
Below Normal, or Shorted to Low Source
3510
3
227
Sensor supply voltage 2
Voltage Above Normal, or
Shorted to High Source
Sensor Supply Voltage #2 Circuit - Voltage
Above Normal, or Shorted to High Source
3510
4
187
Sensor supply voltage 2
Voltage Below Normal, or
Shorted to Low Source
Sensor Supply Voltage #2 Circuit - Voltage
Below Normal, or Shorted to Low Source
3511
3
239
Sensor supply voltage 3
Voltage Above Normal, or
Shorted to High Source
Sensor Supply Voltage #3 Circuit - Voltage
Above Normal, or Shorted to High Source
3511
4
238
Sensor supply voltage 3
Voltage Below Normal, or
Shorted to Low Source
Sensor Supply Voltage #3 Circuit - Voltage
Below Normal, or Shorted to Low Source
3512
3
2185
Sensor supply voltage 4
Voltage Above Normal, or
Shorted to High Source
Sensor Supply 4 Circuit - Voltage above
normal, or shorted to high source
3513
3
1695
Sensor supply voltage 5
Voltage Above Normal, or
Shorted to High Source
Sensor Supply 5 - Voltage Above Normal, or
Shorted to High Source
3513
4
1696
Sensor supply voltage 5
Voltage Below Normal, or
Shorted to Low Source
Sensor Supply 5 - Voltage Below Normal, or
Shorted to Low Source
Содержание 10/110
Страница 2: ......
Страница 4: ......
Страница 12: ...8 GENERAL INFORMATION 7 125 9 115 7 125 10 110 14 90 Fixed Height Braked Variable Height Braked...
Страница 13: ...GENERAL INFORMATION 9 7 125 9 115 7 125 10 110 14 90 KHD Variable Height LRG Less Running Gear...
Страница 69: ...MACHINE SYSTEMS 65 7 125 9 115 7 125 10 110 14 90 IQ Option Harness Schematic 46636749 Rev A sheeet 1...
Страница 70: ...66 MACHINE SYSTEMS 7 125 9 115 7 125 10 110 14 90 Control Panel Haness Schematic 46641699 Rev A sheeet 1...
Страница 71: ...MACHINE SYSTEMS 67 7 125 9 115 7 125 10 110 14 90 Control Panel Haness Schematic 46641699 Rev A sheeet 2...
Страница 72: ...68 MACHINE SYSTEMS 7 125 9 115 7 125 10 110 14 90...
Страница 84: ......