SAFETY INSTRUCTIONS

WARNING! RISK OF INJURY!

Have a qualified technician lay the cables 220–240V AC. The cables must be laid in protective corrugated 

tubes. Avoid contact of cables and moving parts of the door. In case of supply cable damage, use the suitable 

type of the cable.

Materials required for installation of Shaft-20 and relevant accessories (if available):

•  Cable 2 

×

 0.5 mm

2

 (photocell transmitter, stepped control button);

•  Cable 4 

×

 0.5 mm

2

 (photocell receiver);

•  Cable 3 

×

 1.5 mm

2

 (power supply);

•  The cables should be appropriately insulated according to their voltage.

•  When performing operation at height, use a stable support.

•  When drilling holes, use protection for hands and face.

•  For fastening the product, use hardware supplied with the operator or other analogous one.

•  Disconnect the supply, when installation, cleaning or other maintenance is being carried out.

•  If the operator is installed on the door with a built-in pass door, an additional safety device should be installed 

to prevent operator activation when the pass door is open.

•  Make sure that there will be no jamming of objects between moving and fixed operator elements when the door 

is in motion.

•  It  is  highly  recommended  to  use  DoorHan  optional  equipment  as  the  accessories  produced  by  third-party 

manufacturers can damage the automatic system.

•  DoorHan is not responsible for unstable work of the automatic system when using safety devices and accessories, 

which are produced by other manufactures without securing approval of DoorHan.

•  Never leave the electric motors in released condition. This may cause uncontrolled movement of the door leaves 

and, consequently, their breakdown.

•  Do not use the operator if it needs repair or adjustment as defects in operator installation or improperly installed 

door can cause injury.

•  DoorHan  shall  not  be  held  liable  in  case  of  improper  installation  of  the  product  and  damage  arisen  during 

operation.

•  Since the operator does not have a power cord with a plug, the automatic system shall be connected to the 

mains supply via automatic switch with a minimum distance of 3 mm between the neighbouring contacts. It is 

recommended to use a 10А double-pole circuit breaker.

•  Be sure, there are no foreign objects in a zone of operator action prior to its start-up.

•  Do not make any changes in the automatic system not specified in this manual.

•  Remove a package of the product and dispose of it. Keep the package materials away from children.

•  Never permit children to play in the zone of door movement when the operator is working. Always keep all 

operator remote control panels, as well as stationary control buttons out of reach of children.

•  It is allowed to drive or to go only when the door is stopped and the operator is switched off.

•  The content of the manual shall not be a basis for any claim.

•  The manufacturer reserves the right to modify the design of the product and to improve it without notice.

WARNING! 

For safe and correct work of the operator it is necessary to put a mechanical stopper to limit 

door leave travel.

 

The Installation and configuration of the actuator must only be carried out by qualified specialists.

 

 

 

 

   

 

 

 

 

 

   

   

 

After installing the drive, test force according to standards EN 12445 and EN 12453.

 

 

 

 

   

 

 

 

 

 

   

   

Содержание SHAFT-20

Страница 1: ...OR SHAFT 20 DoorHan 2014 Installation and Operating Manual GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION ADJUSTMENT OF EXTREME POSITION MAINTENANCE TROUBLESHOOTING 2 3 5 5 8 9 9 ...

Страница 2: ... a built in release see Section 4 5 Limit switches ensure safe and reliable operation of the operator WARNING Check the torsion springs for correct adjustment regularly if the springs are not adjusted properly the release can cause spontaneous closing of the door GENERAL INFORMATION CONTENTS 1 GENERAL INFORMATION 2 1 1 Basic functions 2 1 2 Technical specifications 3 1 3 Delivery set 3 2 SAFETY IN...

Страница 3: ...ther than intended purposes DoorHan shall not be liable in case of personal injury caused by misuse of the product Prior to installation of the operator make sure that the door is balanced and moves smoothly Installation must be performed in accordance with the standards EN 12453 and EN 12445 These requirements are to be met in non EU countries for ensuring the required safety level Check if the d...

Страница 4: ...er leave the electric motors in released condition This may cause uncontrolled movement of the door leaves and consequently their breakdown Do not use the operator if it needs repair or adjustment as defects in operator installation or improperly installed door can cause injury DoorHan shall not be held liable in case of improper installation of the product and damage arisen during operation Since...

Страница 5: ...ust repair or displace springs which balance the door weight or its brackets by yourself They are stretched with great force and may cause serious injuries It is forbidden to operate the door requiring repair or adjustment as such door defect or incorrect installation may also result in serious injuries Before mounting of the garage door operator it is necessary to check that the door mechanics is...

Страница 6: ...LS 4 5 OPERATOR MANUAL CONTROL The knob of the built in release is used to release the operator It is possible to open and to close the door by hand after the door is released Release operation In order to lift or lower the door in case of a power cut it is necessary to press and to turn the release knob see Figure 2 clockwise against stop upon which the door can be lifted or lowered by hand In or...

Страница 7: ... pos 3 Disconnect a limit switch ring pos 4 and install it on the door shaft pos 3 Install the operator pos 5 on the door shaft pos 3 Install a key pos 6 in the shaft and operator key way check the correct position of the key Fix the operator to the mounting bracket pos 1 by means of three bolts pos 7 Install the limit switch ring pos 4 on the operator shaft Install the locking ring pos 2 closely ...

Страница 8: ...that the screw presses the microswitch and DL2 indicator on the control unit is off Figure 4 Figure 5 5 ADJUSTMENT OF EXTREME POSITIONS 5 1 CLOSED POSITION Make sure that the operator is fixed rigidly put the door in completely closed position Move a ring for extreme position installation pos 1 so that a screw pos 2 would press the upper microswitch pos 3 See Figure 4 Open and close the door make ...

Страница 9: ...ailure the door will stop As soon as power supply is restored you can control the operator as usual After expiration of life time the product shall be delivered to a specialized disposal plant If you have lost this Manual you may request its copy forwarding a letter to the following address Kralovsky VRCH 2018 Kadan 43201 Czech Republic or by email europe doorhan com The producer DoorHan does not ...

Страница 10: ...10 FOR NOTES ...

Страница 11: ...11 FOR NOTES ...

Страница 12: ... our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Republic Telephone 420 474 319 111 E mail europe doorhan com www doorhan cz ...

Отзывы: