6. PROGRAMMING

DIP switches are used to switch between the operating modes of the control unit board. 

WARNING!

 

Prior to switching between the operating modes turn the power supply OFF.

 

When using the device for the first time make sure the DIP switches 1 and 2 are in correct position.

6.1. DIP SWITCHES

Table 6.1.1. DIP switches operation

DCUН-2 operating mode

DCUН-3 operating mode

DIP 1 = Off

DIP 1 = Off

DIP 2 = Off

DIP 2 = On

DIP 3 is used to enter the advanced menu.
DIP 3 = Off (main menu)
DIP 3 = On (advanced menu)

DIP 3 is used to enter the advanced menu.
DIP 3 = Off (main menu)
DIP 3 = On (advanced menu)

DIP 4 is not used

DIP 4 is not used

Menu screen shows dH2

Menu screen shows dH3

In DCUH-2 mode each operation of the door and dock leveler is displayed on the menu screen accordingly (see Ta-
ble 6.1.2).

PROGRAMMING

* Connection scheme refers to DoorHan operators of Shaft series only.

Fig. 5.5. Connection scheme of lip inductive position sensor for DCUH-2 control unit*

Shaft operator 

control post

Lip inductive
position sensor

Shaft operator control board terminals

brown

white

black

blue

red

COM

OPEN

STOP

CLOSE

+24V

Содержание DCUH-2

Страница 1: ...DCUH 2 3 Control Unit for Electro Hydraulic Dock Leveler with Hinged Lip General Information 2 Safety Rules 2 Design 3 Installation 4 Electrical Connections 5 Programming 8 Control Unit Operation 11...

Страница 2: ...Table 1 2 Control units specifications Parameters Value Supply voltage 380 415 V 50 60 Hz Control voltage 24 VDC Max power of the hydraulic station 1 5 kW Operating temperature 20 50 Dimensions W H D...

Страница 3: ...eveler parking button P 5 Dock leveler RAISE button 6 Main power switch 7 Inflatable dock shelter control button 8 Door CLOSE button 9 Door STOP button 10 Door OPEN button Fig 3 1 Closed view 1 2 3 4...

Страница 4: ...it installation Mount the control unit so the distance between control unit bottom and dock floor is approximately 1 1 5 m Choose the fasteners corresponding to the type of wall 4 INSTALLATION Anchor...

Страница 5: ...GND IN 1 DIP X11 X12 X14 X1 24 1 2 3 ON 4 FU X15 X16 X17 X18 X19 X22 X20 X21 FU FU RED M M 380 415 V 380 415 V 0 55 kW GREEN RED GREEN L N N PE PE PE PE L3 L2 L1 6 3 A 6 3 A 6 3 A 5 ELECTRICAL CONNECT...

Страница 6: ...OP CLOSE 24V GND IN 4 24V GND IN 3 24V GND IN 2 24V GND IN 1 DIP X11 X12 X14 X1 24 1 2 3 ON 4 FU X15 X16 X17 X18 X19 X22 X20 X21 FU FU RED M M 380 415 V 380 415 V 0 55 kW GREEN RED GREEN L N N PE PE P...

Страница 7: ...4 24V GND IN 3 X11 FU X18 X19 X20 X21 PHOTOELECTRIC END SWITCH OR CLOSE CLOSE 24V GND IN 4 24V GND IN 3 24V GND IN 2 24V GND IN 1 DI ON X15 X16 X17 X18 X19 white blue blue black black brown brown Fig...

Страница 8: ...nced menu DIP 3 Off main menu DIP 3 On advanced menu DIP 3 is used to enter the advanced menu DIP 3 Off main menu DIP 3 On advanced menu DIP 4 is not used DIP 4 is not used Menu screen shows dH2 Menu...

Страница 9: ...it then press and release the RAISE button After that press the P and RAISE buttons simultaneously and hold for 5 seconds Flashing UH message on the menu screen confirms you have successfully entered...

Страница 10: ...ATION PROGRAMMING Table 6 2 2 Parameters of the DCUH 3 programming menu Message Setting option Description 1 UH Parameter value 1 9 3 11 sec Default value 7 sec Change of value by 1 equals 1 sec Time...

Страница 11: ...the stored position After that turn the main power switch 0FF Auto parking of the leveler Press the P button briefly Wait till the dock leveler re sumes the stored position After that turn the main po...

Страница 12: ...nit Part name Part number 1 DCUH 2 main board PCB_DCUH2 M V 1 1 DCUH 3 main board PCB_DCUH3 M V 1 1 2 DCUH 2 control board PCB_DCUH2 BT V 1 0 DCUH 3 control board PCB_DCUH3 BT V 1 0 3 Switch assembly...