Fig. 4.1. Control unit installation

Mount the control unit so the distance between control unit bottom and dock floor is approximately 1–1,5 m. Choose the 
fasteners corresponding to the type of wall.

4. INSTALLATION

Anchor points

INST

ALLA

TION

Содержание DCUH-2

Страница 1: ...DCUH 2 3 Control Unit for Electro Hydraulic Dock Leveler with Hinged Lip General Information 2 Safety Rules 2 Design 3 Installation 4 Electrical Connections 5 Programming 8 Control Unit Operation 11...

Страница 2: ...Table 1 2 Control units specifications Parameters Value Supply voltage 380 415 V 50 60 Hz Control voltage 24 VDC Max power of the hydraulic station 1 5 kW Operating temperature 20 50 Dimensions W H D...

Страница 3: ...eveler parking button P 5 Dock leveler RAISE button 6 Main power switch 7 Inflatable dock shelter control button 8 Door CLOSE button 9 Door STOP button 10 Door OPEN button Fig 3 1 Closed view 1 2 3 4...

Страница 4: ...it installation Mount the control unit so the distance between control unit bottom and dock floor is approximately 1 1 5 m Choose the fasteners corresponding to the type of wall 4 INSTALLATION Anchor...

Страница 5: ...GND IN 1 DIP X11 X12 X14 X1 24 1 2 3 ON 4 FU X15 X16 X17 X18 X19 X22 X20 X21 FU FU RED M M 380 415 V 380 415 V 0 55 kW GREEN RED GREEN L N N PE PE PE PE L3 L2 L1 6 3 A 6 3 A 6 3 A 5 ELECTRICAL CONNECT...

Страница 6: ...OP CLOSE 24V GND IN 4 24V GND IN 3 24V GND IN 2 24V GND IN 1 DIP X11 X12 X14 X1 24 1 2 3 ON 4 FU X15 X16 X17 X18 X19 X22 X20 X21 FU FU RED M M 380 415 V 380 415 V 0 55 kW GREEN RED GREEN L N N PE PE P...

Страница 7: ...4 24V GND IN 3 X11 FU X18 X19 X20 X21 PHOTOELECTRIC END SWITCH OR CLOSE CLOSE 24V GND IN 4 24V GND IN 3 24V GND IN 2 24V GND IN 1 DI ON X15 X16 X17 X18 X19 white blue blue black black brown brown Fig...

Страница 8: ...nced menu DIP 3 Off main menu DIP 3 On advanced menu DIP 3 is used to enter the advanced menu DIP 3 Off main menu DIP 3 On advanced menu DIP 4 is not used DIP 4 is not used Menu screen shows dH2 Menu...

Страница 9: ...it then press and release the RAISE button After that press the P and RAISE buttons simultaneously and hold for 5 seconds Flashing UH message on the menu screen confirms you have successfully entered...

Страница 10: ...ATION PROGRAMMING Table 6 2 2 Parameters of the DCUH 3 programming menu Message Setting option Description 1 UH Parameter value 1 9 3 11 sec Default value 7 sec Change of value by 1 equals 1 sec Time...

Страница 11: ...the stored position After that turn the main power switch 0FF Auto parking of the leveler Press the P button briefly Wait till the dock leveler re sumes the stored position After that turn the main po...