Ambient and Delta Pressure Switch Installation
Ambient and Delta Pressure Switch Installation
Ambient and Delta Pressure Switch Installation
Ambient and Delta Pressure Switch Installation
Ambient and Delta Pressure Switch Installation
Connect to high pressure
port of pressure switch
Connect to low pressure
port of pressure switch
Cleans each time the main
blower fan is shut down.
Connect to low pressure
port of pressure switch
Ambient
Pressure switch (ref) located
on bottom of control box
2.6.8 Magnehelic Gage Pack
The Magnehelic gage should be installed as
shown in Figure 14.
2.6.9 5-Gallon Pail Insert
55-Gallon Drum Insert
The 5-gallon pail insert assembly is shown in
Figure 15. The perforated plastic insert should be
installed inside the poly bag and the assembly set
in a 5-gallon pail. The top of the poly bag should
fold over the 5-gallon pail and seal against the pail
cover. This will prevent the poly bag from being
sucked into the dust collector. Remove the plastic
insert when the poly bag is full. The plastic insert
can then be reused.
Follow the preceding procedure for 55-gallon
drum inserts installation.
Cleans only when the filter
obtains 3" pressure drop when
the main blower fan shuts
down.
Delta
Pressure Switch
Static Pressure Tee