background image

Donaldson Company, Inc.© 1998

5

section of the cabinet, and exits through the top
clean air outlet.

1.1.2 Filter Cleaning

   RVS collectors are intermittent duty.  

Cleaning

is done only after the fan is shut off and an
appropriate fan run-down time is completed.

   Filter cartridge cleaning is accomplished by high
frequency vibration.

1.0

1.0

1.0

1.0

1.0 INTRODUCTION

INTRODUCTION

INTRODUCTION

INTRODUCTION

INTRODUCTION

The Torit

 

 RVS dust collectors provide high

efficiency, intermittent duty air cleaning by means
of an exclusive Torit filter cartridge. The filter
element is cleaned automatically each time the unit
is shut off unless an optional delta switch system is
included. With the optional delta pressure switch,
the filter is cleaned only after the airflow across
the filter reaches 3" pressure drop.

1.1

1.1

1.1

1.1

1.1 Operational Explanation

Operational Explanation

Operational Explanation

Operational Explanation

Operational Explanation

 (See Figure 2)

 (See Figure 2)

 (See Figure 2)

 (See Figure 2)

 (See Figure 2)

1.1.1 Normal Operation

Dust enters through the cabinet inlet and is

deflected downward by the inlet deflector. It then
passes through a tight mesh screen on the outside
of the filter. The screen, spaced 1-inch away from
the filter media, catches fibrous dust, while fine
particles pass through the screen and collect on the
outside surfaces of the pleated filter cartridge.
Clean air flows up through the center of the filter
cartridge into the blower, through the silencer

Figure 2

Figure 2

Figure 2

Figure 2

Figure 2

Operational Schematics

Operational Schematics

Operational Schematics

Operational Schematics

Operational Schematics

Filter Diaphragm

"Closed"

Filter Element

NORMAL OPERATION

NORMAL OPERATION

NORMAL OPERATION

NORMAL OPERATION

NORMAL OPERATION

Dirty Air

Inlet

Vibrator Motor "Off"

Blower "On"

Silencer Section

Clean Air

Outlet

Blower "Off"

Vibrator Motor "On"

Pleated Filter Media

Fine Mesh Screen

Filter Diaphragm

"Open"

Dust Pan

FILTER CLEANING

FILTER CLEANING

FILTER CLEANING

FILTER CLEANING

FILTER CLEANING

Optional delta switch systems will
follow the cleaning sequence only if
the filter restriction is greater than
the pressure switch set point of 3"
pressure drop (see Figure 13).

Power to collector controls must
remain on to operate cleaning
mechanism.

NOTE

NOTE

NOTE

NOTE

NOTE

NOTE

NOTE

NOTE

NOTE

NOTE

Содержание Torit RVS-10

Страница 1: ...or Without Hopper With or Without Hopper Includes Installation Operation and Service Instructions Includes Installation Operation and Service Instructions Includes Installation Operation and Service I...

Страница 2: ...burning objects or lit cigarettes into the hood or ducting of any dust control system Avoid mixing combustible materials with dust generated from grinding of ferrous metals due to the potential fire h...

Страница 3: ...tion 5 1 1 1 NormalOperation 5 1 1 2 Filter Cleaning 5 6 2 0 Installation 6 2 1 Inspection 6 2 2 Pre Installation 6 2 3 Location 6 2 4 Assembly of Hopper and Separator 8 2 5 Assembly of Hopper and Sep...

Страница 4: ...T iew of T iew of T iew of T iew of Typical RVS Dust Collector ypical RVS Dust Collector ypical RVS Dust Collector ypical RVS Dust Collector ypical RVS Dust Collector Clean Air Outlet Filter Element...

Страница 5: ...inet inlet and is deflected downward by the inlet deflector It then passes through a tight mesh screen on the outside of the filter The screen spaced 1 inch away from the filter media catches fibrous...

Страница 6: ...f the filter cartridge opens after the fan is shut off allowing fine dust particles collected on the filter media to escape The dust falls down into the dust pan or optional hopper for disposal as sho...

Страница 7: ...pper Separator Installation Legs to Hopper Separator Installation Legs to Hopper Separator Installation Legs to Hopper Separator Installation Sealant Crossbraces Sealant Hopper Crossbraces Hopper or S...

Страница 8: ...ments Attachments 2 5 1 Square to Round Inlet Adapter Install the square to round inlet adapter to the separator inlet as shown in Figure 5 2 5 2 55 Gallon Drum Cover Pack Install the 55 Gallon drum c...

Страница 9: ...tion 55 Gallon Drum Cover Pack Installation 55 Gallon Drum Cover Pack Installation O Ring Gasket Round VS Collar Clamp Drum Cover Drum Ref Supplied by Others Figure 7 Figure 7 Figure 7 Figure 7 Figure...

Страница 10: ...igure 9 Figure 9 40 Liter Pail Pack Installation 40 Liter Pail Pack Installation 40 Liter Pail Pack Installation 40 Liter Pail Pack Installation 40 Liter Pail Pack Installation Cabinet Clamp Sight Gla...

Страница 11: ...top cover and retain 8 M8 15mm bolts 2 Set silencer pack on top of cabinet as shown 3 Use rubber seal between silencer and top of cabinet as needed 4 Fasten silencer to cabinet using 8 M8 15mm bolts 2...

Страница 12: ...t hopper cabinet only 2 Install 4 rivnuts in the enlarged cabinet holes per drilling detail 3 Apply sealant to the outside of the cabinet bolt circle 4 Secure the base plate to the cabinet with two bo...

Страница 13: ...els RVS 5 10 15 Casters M8 x 70mm Lg Bolts Nuts Washers 4 M8 x 20mm Lg Bolts Nuts Washers 16 Outrigger Weldment Front View 2 6 6 Outrigger Package If the RVS collector has an Outrigger package install...

Страница 14: ...l box 2 6 8 Magnehelic Gage Pack The Magnehelic gage should be installed as shown in Figure 14 2 6 9 5 Gallon Pail Insert 55 Gallon Drum Insert The 5 gallon pail insert assembly is shown in Figure 15...

Страница 15: ...n Pail Insert 55 Gallon Drum Insert 5 Gallon Pail Insert 55 Gallon Drum Insert 5 Gallon Pail Insert 55 Gallon Drum Insert 5 Gallon Pail Insert 55 Gallon Drum Insert 5 Gallon Pail Insert 55 Gallon Drum...

Страница 16: ...ed by Torit 115 VAC P2 Pressure Switch white wired by Torit In grounded systems the L2 wire must be connected to the ground terminal to the transformer 110VACneutral NOTES 1 All electrical work must b...

Страница 17: ...the gate The collector fan does not need to be shut off if this procedure is followed 3 0 3 0 3 0 3 0 3 0 ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL 1 Make electrical connections to the d...

Страница 18: ...ter Element Filter Element Filter Element If the fine mesh screen on the filter becomes plugged with fibrous material it can be removed and cleaned Clean with cold water only To remove the screen simp...

Страница 19: ...ilter Replacement A slight bleed through on any new filter is normal and will quickly disappear as the filter seasons CAUTION CAUTION CAUTION CAUTION CAUTION 7 Inspect the door gasket on the cabinet a...

Страница 20: ...ce fuse with MDX 3 amp fuse only Other types of fuses may cause shaker motor damage 2b Using a volt ohm meter check the output voltage at terminals X1 and X2 on the transformer must be 115 volts AC If...

Страница 21: ...seconds minimum for the timing sequence to start The Delta control starts the shake cycle only after the filter element obtains a 3 pressure drop reference Figure 13 Ambient and Delta Pressure Switch...

Страница 22: ...er instructions 2b Check the motor internal wiring connections and motor cable connections Correct if needed reference Motor Manufacturer s Wiring Diagram 3a Remove the upper door and check for proper...

Страница 23: ...ker arm or replace the shaker assembly completely 1a Rewire per local and national codes for proper wire size 1b Check and correct internal motor wiring for proper connections for your voltage referen...

Страница 24: ...d 3 Remove and replace if the ducting is collapsed Remove and clean out debris that is blocking the ducting 4 Check with your local Torit representative for information 5 Check the fan exhaust area fo...

Страница 25: ...velcro seam for easy installation and removal The screen must be stretched tightly around the filter and located all the way to the top of the filer end cap covering the perforated liner completely r...

Страница 26: ...ormer Voltage Table Transformer Voltage Table Transformer Voltage Table Transformer Voltage Table Transformer Voltage Table TRANSFORMER H1 H2 H3 H4 H5 H6 X2 X1 INPUT VOLTAGE H1 H2 H1 H3 H1 H4 H1 H5 H1...

Страница 27: ...sembly Control Box Assembly Control Box Assembly Control Box Assembly O N CTS 60 30 Clean 180 Wait Time 60 Time 90 Sec Detail C 01 Single RVS 5 10 15 All switches preset to OFF position Default set to...

Страница 28: ...rol Box Assembly Control Box Assembly Control Box Assembly Control Box Assembly 1 2 3 4 Timer Control 60 30 Clean 180 Wait Time 60 Time 90 Sec Detail C 01 Single RVS 5 10 15 All switches preset to OFF...

Страница 29: ...osure 1T3 1T2 1T1 230V WHT BLK 115V ControlEnclosure Fan Mtr MDX 3 3AMP Slo Blo 125 VAC P2 AC IN WHT WHT GRN GRN BLK WHT Timer PC Board M1 VIB Mtr 1 8 HP 115 60 1 Wiring by Torit Wiring by Others Figu...

Страница 30: ...re not manufactured by seller and is expressly in lieu of all other warranties expressed or implied including any warranty or merchantability or fitness for a particular purpose or use There are no wa...

Отзывы: