Donaldson Company, Inc.© 1998
25
7.0 TROUBLESHOOTING GUIDE
TROUBLE
REMEDY
POSSIBLE CAUSE
F.
Insufficient air flow
(cont).
6. Filter element plugged with
dust.
a. Filter screen not in place.
b. Plugged filter screen.
7. Dust storage area is over full,
plugging inlet and filter area.
8. Shaker mechanism is not
working.
6. Remove and replace filter
cartridge (reference Parts List
and Figure 16 Filter
Replacement).
6a. Check the filter screen to
make sure that is has not slid
down. The screen has a
velcro seam for easy
installation and removal.
The screen must be stretched
tightly around the filter and
located all the way to the top
of the filer end cap, covering
the perforated liner
completely (reference Figure
17 Filter Replacement).
6b. If the filter screen is plugged,
remove and wash in cold
water only. Note:
Hot water
will cause screen shrinkage.
To reinstall, reference
Figure 17 Filter Replacement.
7. Empty the dust pan or hopper,
drum/pail area. Reinstall the
drum, pails/dust drawer after
emptying and secure all
doors.
8. Check the shaker mechanism
or electrical controls.
Reference Section C1, 2,
and 3 in this troubleshooting
guide.
Reference Drawings
2SG-40533-00 Single VS