![Donaldson DLM V Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/donaldson/dlm-v-series/dlm-v-series_installation-operation-and-maintenance-manual_2520626034.webp)
34
Installation, Operation and Maintenance Manual
Dalamatic Insertable Dust Collectors – Series DLM V
SPECIFICATION
6.9 bar (100 psig)
Design pressure:
Manifold volume:
Maximum operating
pressure, PS:
TABLE 5 – COMPRESSED AIR MANIFOLD DESIGN DETAILS
10.35 bar (150 psig)
Test pressure:
30
q
to
150
q
C
Design temperature:
Maximum rating of
pressure relief device:
25 dm³/s at 7.1 bar (factory set at 7.1 bar)
(not supplied as standard)
6.23 litres (DLM V3/7 and V5/12 collectors)
9.55 litres (DLM V4/7, V6/10, V7.5/12 and V9/15 collectors)
17.14 litres (DLM V7/7, V10/10, V13/12 and V15/15 collectors)
13.61 litres (DLM V8/7, V12/10, V15/12 and V18/15 collectors)
24.37 litres (DLM V14/7, V20/10, V21/7, V25/12, V30/10, V30/15, V38/12,
V45/15, V50/12 and V60/15 collectors)
Product of pressure
and capacity:
38.63 bar litres (DLM V3/7 and V5/12 collectors)
59.21 bar litres (DLM V4/7, V6/10, V7.5/12 and V9/15 collectors)
106.27 bar litres (DLM V7/7, V10/10, V13/12 and V15/15 collectors)
84.38 bar litres (DLM V8/7, V12/10, V15/12 and V18/15 collectors)
151.09 bar litres (DLM V14/7, V20/10, V21/7, V25/12, V30/10, V30/15,
V38/12, V45/15, V50/12 and V60/15 collectors)
Structural hollow section
Material used for
manifold construction:
Minimum metal
thickness before
manifold requires
special inspection:
To improve corrosion resistance the manifold is painted externally and
internally using cathodic electrocoat.
5.5 mm (DLM V3/7, V4/7, V5/12, V6/10, V7/7, V7.5/12, V9/15, V10/10,
V13/12 and V15/15 collectors)
7.0 mm (DLM V8/7, V12/10, V14/7, V15/12, V18/15, V20/10, V21/7, V25/12,
V30/10, V30/15, V38/12, V45/15, V50/12 and V60/15 collectors)
1 bar = 10
5
Pa
6.2 bar (90 psig)