Dalamatic Insertable dust collectors are delivered partly assembled. Final
assembly of each collector is as follows:
Mounting over aperture
1 Check that the aperture and fixing holes are correct
in size and position to suit the mounting-flanges of
the Dalamatic collector (if required, aperture and
mounting flange details are provided in Publication
364).
2 Apply a continuous 5 mm bead of sealing
compound all round aperture, along each side of
the fixing holes, as shown.
3 Arrange lifting tackle to suit mode of insertion (fig. 2).
On V60/15 and V50/12 collectors, for 4 point lift – vertical insertion.
On exit header, weather cowl and fan versions (with or without
acoustic diffuser) lift by means of the 4 eyebolts fitted to the exit
header top.
Chains or slings should be used with an adequate SWL (Safe Working Load).
(Refer to lifting label located adjacent to lifting bracket for weight of equipment
supplied by Donaldson).
Chains must be long enough to ensure that the included angle between
diagonal chains is not greater than 90
q
.
4 Lift and position the collector body until the mounting-flange is seated in
position over the aperture. Match up fixing-holes, install bolts, washers and
nuts and tighten down all round to form an airtight seal.
For Insertable dust collectors mounted on a housing it is
recommended that the housing be lifted into position before
installation of the collector body. Most housings are fitted with
brackets for lifting, however if these are not available a suitable
sling arrangement should be used. If there is a requirement to lift
both the collector body and housing together, the collector body
brackets can be used for vertical insertion, provided the weight
of the housing is less than 600kg (refer to lifting label for section
weight). For horizontal insertion the use of the collector body lifting
brackets alone is not permitted, it is then necessary to also use
the housing lifting brackets or a suitable sling arrangement to give
additional support.
Fixing bolts etc. are not supplied by Donaldson.
INSTALLATION