27
Donaldson Company, Inc.
Acoustic Curtain for Power Module
1. Install the acoustic curtain to the front of the power
module by aligning the acoustic curtain holes with
the non-louvre door holes and secure with nylon
Christmas Tree
™
clips.
Christmas
tree clips
power module
Acoustic Curtain Assembly
Light Fixture
Electrical work must be
performed by a qualified
electrician and comply with all applicable
national and local codes.
Turn power off and lock out electrical
power sources before performing service or
maintenance work.
Do not install in classified hazardous
atmospheres without an enclosure rated for
the application.
Dust-Tight
1. Bolt the mounting angles to the roof panels with
M8-1.25 x 20 mm bolts, flat washers, and hex nuts.
2. Drill two 11/32-in holes in the center of the 2.25-in
diameter boss stamped in the fixture housing.
3. Using the holes drilled in Step 2, attach the fixture to
the mounting angles using M8-1.25 x 20 mm bolts, flat
washers, and hex nuts.
4. Wire the fixture following the wiring diagram
included with the fixture.
5. Install customer-supplied fluorescent bulbs.
mounting angle
light fixture
M8 x 20mm
bolt
M8 flat washer
M8 hex nut
0.34-in
diameter
Detail A
industrial or dust-tight
light fixture
mounting angle
see Detail A
Light Fixture Installation
Содержание DWS 4-1
Страница 11: ...Downflo Workstation DWS 4 1 to 6 4 8 This Page Intentionally Left Blank ...
Страница 20: ...17 Donaldson Company Inc Solenoid Enclosure ...
Страница 42: ...39 Donaldson Company Inc Service Notes Date Service Performed Notes ...
Страница 43: ......