A-7
Donaldson Company, Inc.
7. Locate the cleanest section of bag closest to the
collar, making sure there is enough bag to collapse
into a tight bundle without stretching the bag too
tight.
8. Wrap and hand tighten two cable ties around the
collapsed bag section between the collar and filter
cartridge, spacing the cable ties approximately 1/2-
in apart.
9. Compress as much air as possible from the BIBO
bag and BIBO bag extension.
10. Securely tighten the two cable ties with the supplied
cable tie tool at the maximum setting.
11. Cut the compressed BIBO bag between the two
cable ties leaving one tie around each section.
12. Place tape over the cut end of the BIBO bag
containing the filter and both cable ties.
13 Securely wrap tape around the cut end of the bag
covering a minimum of 3-inches around the bag end.
14. Properly dispose of the BIBO bag containing the
filter.
15. If collector contains two filters per opening,gently
push the stub into the collar.
16. Open a new bag and place the open end around the
bag collar as close to the collector as possible. The
bag stub is now inside the new bag.
17. Loosen the safety strap, slide the new bag under the
strap, and the bag stub toward the end of the collar.
Tighten the safety strap to hold the new bag only and
carefully remove the bag stub from the collar.
18. Use the filter ejector rod to pull the second filter
toward the bag collar until within reach.
19. Repeat steps 5-14.
Tape Wrap (Steps 10-13)
1/2-inch
cable ties
BIBO bag or
bag stub
attached to collar
Tape Wrap (Steps 14-17)
3-inches
Tape covering
a minimum of
3-in around
bag stub and
cable ties.
Содержание DFE 2-4
Страница 42: ...A 1 Donaldson Company Inc Appendix A Clean Change Bag In Bag Out Filter and Liner System...
Страница 56: ...B 2 Donaldson Company Inc Service Notes Date Service Performed Notes...
Страница 57: ...Downflo Evolution DFE 2 8 to 5 80 B 3 Date Service Performed Notes...
Страница 58: ...B 4 Donaldson Company Inc Date Service Performed Notes Service Notes...