13
Donaldson Company, Inc.
Start-Up
1. Turn compressed-air supply ON.
2. Turn the equipment being served ON.
3. Turn timing controls ON.
4. Turn main fan ON, if equipped.
Shut Down
Follow this shutdown procedure to clear residual
deposits from the filter bags, filter body, and equipment
served:
1. Turn main fan OFF, leaving compressed air supply ON
to allow off-line filter cleaning.
Note: Contact your Donaldson representative for
shutdown instructions for explosion vented
units.
2. Wait 10 to 15 minutes and turn timing controls and
compressor OFF.
Preliminary Start-Up Check
Instruct all personnel on safe use and maintenance
procedures.
Electrical work during
installation, service or
maintenance must be performed by a qualified
electrician and comply with all applicable
national and local codes.
Turn power off and lock out electrical
power sources before performing service or
maintenance work.
Turn compressed air supply OFF and bleed
lines before performing service or maintenance
work
Check that the collector is clear and free of all
debris before starting.
Do not install in classified hazardous
atmospheres without an enclosure rated for
the application.
Optional fans over 600 lbs must be
independently supported.
1. Check all electrical connections for tightness and
contact.
2. Check for proper rotation as noted on the fan
housing.
To reverse rotation, single-phase power supply:
Follow manufacturer’s instructions on the motor’s
nameplate.
To reverse rotation, three-phase power supply:
Switch any two leads on the motor junction box.
Do not interchange a power lead
with the ground wire. Severe
damage or personal injury may result.
3. All access panels should be sealed and secure.
4. Check that the dust container is properly sealed and
clamped.
5. Check that exhaust damper is set to the fully-closed
position.
6. Check and remove all loose items in or near the inlet
and outlet of the unit.
7. Check that all remote controls and solenoid
enclosures (if applicable) are properly wired and all
service switches are in the OFF position.
8. Check that all optional accessories are installed
properly and secured.
9. Turn power ON at source.
10. Turn the compressed-air supply ON. Adjust pressure
regulator for setting in Compressed Air Requirements
table.
11. Turn blower fan motor ON.
Do not look into fan outlet to
determine rotation. View the fan
rotation through the back of the motor.
Check that the exhaust plenum is free of tools
or debris before checking blower/fan rotation.
Stand clear of exhaust to avoid personal injury.
12. Adjust airflow with the exhaust damper.
Excess airflow can shorten filter
life, cause electrical system
failure, and blower motor failure.