Dalamatic, DLMV
12
L1
L2
ground lug
120V
1
2
3
4
pulse jet
sequencer
L2
white
printed circuit board black edge connector removable to facilitate field wiring
Use diagram provided with unit
SEQ1
L1
red
12-core cable
to terminal boxes
black red yellow blue green gray pink brown purple white orange
solenoid
valves
SV1
SV2
SV3
SV4
SV5
SV6
SV7
SV8
SV9
SV10
L1
L2
solenoid
commons
1
2
3
4
5
6
7
8
9
10
delta P
terminals
interlock
terminals
1
2
3
4
5
6
7
8
9
10
C
6
7
8
9
10
1
2
3
4
5
black
red
yellow
blue
green
gray
pink
brown
purple
white
orange
jumper for 10
compartment
cleaning
200
110
60
1
Solid-State Timer Typical Wiring Diagram
Input
105-135V/50-60Hz/1Ph
Output Solenoids
The load is carried and turned ON and OFF by the 200
watt maximum-load-per-output solid-state switch.
Pulse ON Time
Factory set at 100-milliseconds, or 1/10-second.
Do not adjust pulse ON time
unless the proper test equipment
is available. Too much or too little ON time can
cause shortened filter life.
Pulse OFF Time
Factory set at 10-seconds, adjustable from 1.5-sec
minimum to maximum 30-seconds.
Operating Temperature Range
-20° F to 130° F
Transient Voltage Protection
50 kW transient volts for 20-millisecond duration once
every 20 seconds, 1% duty cycle.
Solenoid Valves
115-Volt at 19.7 watts each
Compressed-Air
Set compressed-air supply at 90-psig. The timer is
factory set to clean one filter or set of filters every
10-seconds.
Do not increase supply pressure
above 100-psig. Component
damage can occur.