37
BIOCLASS iC DX
Nº. Parameter
Display
10
Registration of the boiler in
iConnect
.
11
Screen contrast setting.
(*) When the boiler is registered in iConnect, these settings will be adjusted through
the app.
IMPORTANT NOTE: It is strongly recommended that the user activate the "Ashtray
emptying warning" function (see point 5 of the configuration
menu and paragraph 11.6), to avoid a malfunction of the boiler
due to premature fouling and a fire.
The following sections describe in detail all the parameters included in the
"Configuration Menu".
11.1
Timers programming process
The
Bioclass iC DX
boiler allows you to set up to 3 different daily time schedules, time schedule for
the boiler, time schedule for the automatic pellet loading system (if connected) and time schedule for
the DHW recirculation pump (if this function is activated , see "Technical Menu"). By default, if no
programming adjustment has been made, the boiler is supplied with the hourly programming disabled,
that is, the boiler and / or the programmable function will remain active 24 hours a day (the
corresponding screen will display the digits "- - - -").
In turn, each of the heating zones that may have been installed in the boiler (up to a maximum of 3
zones) can have their own time programming if they have a room sensor connected. By default, the
boiler comes with the heating time schedule disabled (the digits "
- - - -
" are displayed on the
programming screen), that is, the user will manually adjust the desired temperature setpoint at each
moment of the day using the corresponding screen of the "User" menu.
The adjustment process, described below, will be the same for any of the time schedules mentioned
above. Once the time programming to be adjusted has been selected by pressing
, it is accessed
and SET will light up flashing, starting the adjustment process.
If a heating time schedule is selected, first go to the settings screens of the room temperature setpoints
applied during the scheduled periods of "Comfort" temperature ( ) and the periods of "Reduced"
temperature ( ). Touch the "
+
" or "
-
" heating symbols
(18)
to select this temperature: