Evolution Solar HDX
12
4.2
Changing from dual duct fume removal to coaxial fume removal
The Evolution Solar HDX boiler has a Ø80 dual duct system for combustion product removal and air
intake. If you prefer the combustion products to removed by means of a Ø80/125 coaxial tube, you
may use the Ø80/125 coaxial tube adaptor kit (supplied to order), code CGAS code
CGAS000222.
Adaptor for coaxial tube
80/125
Code CGAS CGAS000222
The changeover may be made with two different assembly configurations:
1. Rear outlet: simply remove the combustion air intake from the boiler, unscrewing the three
screws holding it in place, mount the adaptor on the fume outlet towards the rear, and use the
flexible air inlet tube to connect it to the adaptor T.
2. Side or top outlet: the procedure is the same, but for side mounting of the adaptor kit a 90º
Ø80 elbow (code CGAS000147) needs to be fitted before the adaptor at the fume outlet.
The two configurations are shown in the figures below:
Combustion air intake
Rear outlet
Side outlet
Codo 90º Ø100
Cód. CGAS000267