Evolution Solar HDX
38
19.2
Evolution Solar 30 HDX with SRX2 / EV underfloor heating kit
F:
Phase.
N:
Neutral.
BA:
Solar capture pump.
BC
1
:
Heating pump, circuit nº 1.
BC
2
:
Heating pump, circuit nº 2.
BV:
Domestic hot water pump.
M:
3-way valve motor.
V3V:
Floor heating mixing valve.
Q:
Burner.
bc10:
Burner terminal nº 10.
BS:
Solar pump.
E20:
E20 remote control (optional).
TA
1
:
Room thermostat, circuit nº 1.
TA
2
:
Room thermostat, circuit nº 2.
SC:
Boiler sensor.
Sacs:
Domestic hot water sensor.
Sr:
Underfloor heating sensor.
Si:
Lower solar accumulator sensor.
Scol:
Solar collector sensor.
J
1
:
Supply connector.
J
2
:
Component connector.
J
3
:
Sensor connector.
J
4
:
Remote control connector.
J
5
:
Room thermostat connector 1.
J
6
:
Room thermostat connector 2.
J
7
:
Phone relay connector.
J
8
:
Leading power connector.
J
9
:
V3V connector underfloor.
PWMc:
Heating Cable PWM.
PWMs:
PWM Solar Cable.