Dometic STIIC Скачать руководство пользователя страница 3

3

EN

STIIC Controller 

General Information

1 .3  Supplemental Directives

To reduce the risk of accidents and injuries, please 

observe the following directives before proceeding to 

install or operate this appliance:

•  Read and follow all safety information and 

instructions.

•  Read and understand these instructions before 

installing or operating this product.

•  The installation 

must

 comply with all applicable local 

or national codes, including the latest edition of the 
following standards:

U .S .A .

 

– American Boat and Yacht Council (ABYC)

 

– ANSI/NFPA70, National Electrical Code (NEC)

1 .4  General Safety Messages

 

WARNING: ELECTRICAL SHOCK, FIRE, AND/
OR EXPLOSION HAZARD . Failure to obey the 
following warnings could result in death or 
serious injury:

•  Use only Dometic replacement parts and 

components that are specifically approved for use 
with the appliance.

•  Avoid improper installation, adjustment, alterations, 

service, or maintenance of the appliance. Service and 
maintenance 

must

 be done by a qualified service 

person only.

•  Do 

not

 modify this product in any way. Modification 

can be extremely hazardous.

•  Use care when diagnosing and/or adjusting 

components on a powered unit. 

2  General Information

The Dometic STIIC Programmable Logic Controller 

(PLC) provides a plug and play networking solution 

for Dometic products. The user-friendly software 

connects a vessel’s Dometic devices and systems, like 

air conditioning, water makers, ice makers, refrigeration 

systems, and shipwide ventilation systems, to the 

STIIC PLC. This technology allows the user to monitor, 

manage, and troubleshoot the vessel’s marine comfort 

systems from anywhere in the world, using  a mobile 

device or the Internet.

This is a MODBUS and CANBUS networked system. 

The STIIC PLC is designed to work with unit controllers, 

not to replace them. While the STIIC PLC allows you 

to monitor and perform basic actions for the devices 

enabled in the system, any in-depth diagnostics must be 

done through the individual device or system.

 

I

The images used in this document are for reference 

purposes only. Components and component 

locations may vary according to specific product 

models. Measurements may vary ±0.38 in.  

(10 mm).

Содержание STIIC

Страница 1: ...L UNITS L 5501 Form No 340945 12 19 2019 Dometic Corporation WARNING Cancer and Reproductive Harm www P65Warnings ca gov STIIC EN Smart Touch Integrated Intelligence Control STIIC Installation and Operation Manual 2 ...

Страница 2: ...and Canada 22 10 2 All Other Regions 22 Contents Service Center Dealer Locations Visit www dometic com Read these instructions carefully These instructions MUST stay with this product 1 Explanation of Symbols and Safety Instructions This manual has safety information and instructions to help you eliminate or reduce the risk of accidents and injuries 1 1 Recognize Safety Information This is the saf...

Страница 3: ...alified service person only Do not modify this product in any way Modification can be extremely hazardous Use care when diagnosing and or adjusting components on a powered unit 2 General Information The Dometic STIIC Programmable Logic Controller PLC provides a plug and play networking solution for Dometic products The user friendly software connects a vessel s Dometic devices and systems like air...

Страница 4: ...tion describes the buttons on the touchscreen display q w e r t y 2 Touchscreen Display q STIIC PLC Configuration r Eskimo Ice Systems wAir Conditioning tFAMU SWV eRefrigeration yReverse Osmosis No Button Description q STIIC Configuration Tap the button to open the configuration menus used for Enabling disabling devices Technical support monitoring through a VNC Virtual Network Computing server Na...

Страница 5: ...e STIIC PLC I O layout 3 STIIC PLC I O Layout 2 3 1 PLC Inputs The PLC Input Table describes the inputs for the STIIC PLC I IIf a temperature sensor is defective or not connected the STIIC PLC generates an alarm for that sensor PLC Input Table Input I O Description Port Configuration MBM_FB2 J26 Connection port for Dometic devices to communicate with the STIIC PLC Baudrate 19200 Data length 8 Stop...

Страница 6: ...er PLC 2 Slave PLC VARC Chiller 1 3 XTC Seawater 1 11 ZTC Freshwater 1 13 XZ Combination System 1 15 SWV 1 20 MODBUS Converter 4 30 33 KRA 1 3 40 42 KRA 2 3 43 45 KRA 3 3 46 48 KRA 4 3 49 51 KRA 5 3 52 54 KRA 6 3 55 57 FAMU 1 60 3 Intended Use The STIIC PLC application technology simplifies integration to ship wide network control systems This allows one connection point for third party software d...

Страница 7: ...dity 5 to 85 relative humidity non condensing Protection Rating IP65 front IP20 rear Degree of Pollution Degree II Standards of Compliance Compliant with European EMC and LVD directives UL Certification PLC Technical Specifications Physical Dimensions H x W x D 4 4 in x 8 96 in x 2 4 in 110 mm x 227 5 mm x 60 mm Assembly DIN rail in accordance with DIN 43880 and IEC EN 50022 Panel Environmental Co...

Страница 8: ...5 Wiring Diagram Figure 4 and Figure 5 provide examples of the wiring diagram and terminal connections used for STIIC PLC 4 STIIC PLC Wiring Diagram with 4 Room Controls 2 KRA units VARC Chiller ZTC SpotZero SeaXchange and 2 Touchscreens ...

Страница 9: ...9 EN STIIC Controller Intended Use 5 Device Terminal Connections ...

Страница 10: ...ed units only to MODBUS feedthroughs Wire CANBUS controlled units only to CANBUS feedthroughs Refer to Figure 5 on page 9 and the Connection Port Table on page 10 for information on the correct port to use when connecting Dometic devices to the STIIC PLC Connection Port Table Dometic Devices Connection to STIIC PLC Platinum Chiller MODBUS Communication VARC Chiller MODBUS Communication Fresh Air M...

Страница 11: ...speed or five speed option depending on the thermostat installed This section describes how to configure the STIIC PLC by updating the status of a device setting a fan speed option for room controls and when necessary setting up a static IP address for network configuration 6 3 1 Using the Touchscreen to Enable Disable Devices 1 On the Main screen tap STIIC CONFIGURATION 8 Touchscreen Main Screen ...

Страница 12: ...m control display 14 Room Control Fan Speed Setting Switch 6 3 3 Using the Touchscreen for Setting Up Room Controls and KRAs 1 On the Main screen tap STIIC CONFIGURATION to enter the STIIC Configuration screen 2 Tap Room Controls Naming 15 STIIC Configuration Screen 3 Verify the room control CANBUS ID on the room control and use the drop down menu to change the name based on the ID 16 Device Namin...

Страница 13: ...isplay the Remote Support screen from the Main screen 1 On the Main screen tap STIIC CONFIGURATION The STIIC Configuration screen appears 2 Tap the red phone icon next to Enable Remote Support 19 STIIC Configuration Screen The MobileVNC Settings dialog box appears 20 MobileVNC Settings Dialog Box 3 Tap the Control tab 4 Tap Start to enable remote access 5 Note the IP address next to the pGD TOUCH ...

Страница 14: ...LCD Display to Configure Room Control 1 Press Program to enter the Main menu and scroll to the room controls 25 Main Menu Screen 2 Select a Room Control and press Enter I IThe first selection in the Room Control screen is to select a fan speed Verify which model you have to select the appropriate setting 26 Room Control Screen 3 Press Enter to update the fan speed value 0 3 speed 1 5 speed 27 Fan ...

Страница 15: ...on describes the features available for control of the devices tied to the STIIC PLC 7 1 Accessing a Device Type From the Main screen select the icon of the type of device you wish to control 33 Main Screen 7 2 Managing an Air Conditioning Device This section describes how to manage a Chiller or Room Control device enabled on the system 7 2 1 Managing the Chiller Control To access the Chiller syst...

Страница 16: ...d 2 Enter the temperature within the range specified and tap OK 7 2 2 Managing the Room Controls To access the room controls from the Main screen tap AIR CONDITIONING and tap ROOM CONTROLS 37 Air Conditioning Main Screen This is the main screen for room controls Tap the specific room to view details or use Global Control to set the mode and temperature set points for all rooms 38 Room Control Main...

Страница 17: ...ries condensing units enabled on the system 1 To access the KRA controls from the Main screen tap REFRIGERATION 41 KRA Main Menu Screen The main KRA menu appears listing the enabled condensing units 2 Perform one of the following actions Tap the drop down menu to change the KRA Unit of Measurement Tap the button for the KRA you wish to monitor When a KRA is selected the settings screen for the KRA...

Страница 18: ...maximum of three Eskimo Ice machines that can be viewed on the STIIC PLC To access the Eskimo Ice controls from the Main screen tap ESKIMO ICE 45 Eskimo Ice Main Screen The main Eskimo Ice screen appears listing the available Eskimo Ice machines Select the machine you want to view Perform one of the following actions Turn the machine on or off View the machine status Full or Filling while running ...

Страница 19: ...ic approved technicians can access these options 7 5 2 Using the Shipwide Ventilation Controls To access the SWV controls from the Main screen tap FAMU SWV and tap SHIPWIDE VENTILATION 48 Shipwide Ventilation Main Screen The Shipwide Ventilation Main screen displays Perform one of the following actions Place the system in Auto or Manual mode Stop the system View the system status View the intake a...

Страница 20: ...ero The ZTC SpotZero Main screen displays 51 ZTC SpotZero Main Screen Perform one of the following actions Monitor the pump status Monitor the valve status View the amount of water produced 7 6 3 Using the XZ Series Combination Control To access the XZ Series controls from the Main screen tap REVERSE OSMOSIS and tap Combination XZ The XZ Series Main screen displays 52 XZ Series Main Screen The com...

Страница 21: ... log once the alarm is resolved Tap the clock icon to view the alarm history screen The Historical Alarms screen displays all recorded alarms 55 Historical Alarms Screen Perform one of the following actions Use the drop down menu to change the time interval for the alarm history displayed Select Back or Forward to move between the pages of history To access the alarms screen when the system is not...

Страница 22: ...recycling waste bins whenever possible Consult a local recycling center or specialist dealer for details about how to dispose of the product in accordance with all applicable national and local regulations 10 Warranty Information Refer to the sections below for information about warranty and warranty support in the US Canada and all other regions 10 1 United States and Canada LIMITED WARRANTY AVAI...

Страница 23: ...23 EN STIIC Controller ...

Страница 24: ...com dealer YOUR LOCAL SUPPORT dometic com contact YOUR LOCAL SALES OFFICE dometic com sales offices A complete list of Dometic companies which comprise the Dometic Group can be found in the public filings of DOMETIC GROUP AB Hemvärnsgatan 15 SE 17154 Solna Sweden ...

Отзывы: