13
The refrigerator is later pushed into the instal-
lation recess from the front. Ensure that the
seals abut the case evenly.
This installation option facilitates the removal
and installation of the appliance for servicing.
The cavity in-between the outer vehicle wall
and refrigerator is completely isolated from the
vehicle interior. Intrusion of exhaust fumes into
the living space is prevented. Fumes will esca-
pe through the upper ventilation grille to the
outside.
The draught-proof installation does not requi-
re a special exhaust gas duct to be used.
Fig. 9
Fasten the sealing lips to a stop bar on the
rear side
(1)
, e.g. by gluing.
Proposal 2
The lip seals
(1)
are installed at the bottom and
on each side in the installation recess (Fig. 6-
8). A heat deflector plate
(2)
is installed in the
installation recess above the refrigerator.
Affix
this plate to the caravan wall, do NOT
attach to the refrigerator !
Insert deflector plate in such a way that the hot
air escapes through the air vent grille into the
open air.
Fig. 7
Fig. 6
Fig. 8
1
1
2
2
Proposal 1
Installation
Deviations require the consent of the
manufacturer !
i
1
289 0318-80_EN_RMF-C_85xx-Installation_N1_Layout 1 10.09.2013 12:48 Seite 13
Содержание RMF8500
Страница 28: ...26 Circuit diagram RMF 85x1 RMF 85x5 Fig 51 1 C D B A Installation 4 8 5 Circuit diagrams...
Страница 34: ...4 Dometic GmbH 2013 nderungen vorbehalten Dometic GmbH In der Steinwiese 16 D 57074 Siegen www dometic com...
Страница 46: ...16 Einbau Abb 16 3 Abb 17 4 Luftkanal Warmluft Kaltluft Warmluft Kaltluft 3 Abb 18 Warmluft Kaltluft W rmestau...
Страница 56: ...26 Schaltschema RMF 85x1 RMF 85x5 Abb 51 1 C D B A Einbau 4 8 5 Schaltschemata...
Страница 59: ...29 Installation...