DC control is required to maintain the automatic energy
system). The connection is made to the positive (+) and
negative (-) terminals of the terminal block on the back
of the refrigerator. (See FIG. 1). Correct polarity must be
observed when connecting to the DC supply.

Do not use the chassis or vehicle frame as one of the
conductors. Connect two wires at the refrigerator and
route to the DC supply.

The distance the current must travel from the battery to
the refrigerator dictates the AWG wire size to be used.
Should the wire be too small for the distance, a voltage
drop will result.
Recommended wire sizes are shown below.

Maximum total conductor wire length in feet and meters.

RM 1272

2-way

min. wire

size

17 ft.

14 AWG

5 m

27 ft.

12 AWG

8 m

The wires from the battery to the refrigerator must be of
large enough size to handle the load. The connections
must be clean, tight and free from corrosion.

INSTALLING REFRIGERATOR IN
ENCLOSURE

The transport support at the rear of the refrigerator can
be removed if necessary for the installation of the refrig-
erator in the enclosure. (See figure above).

NOTE: DO NOT install the appliance directly on

carpeting. Carpeting must be removed or
protected by a metal or wood panel be-
neath the appliance which extends at least
full width and depth of the appliance.

NOTE: A wood strip must be in place across the upper
opening of the enclosure. The top frame of the refriger-
ator will be anchored to the wood strip with screws,
see FIG. 10.

The refrigerator must be installed in a substantial enclo-
sure and must be level. When installing the refrigerator
in the enclosure, all areas within the recess in which the
refrigerator is installed must be sealed.
Make sure that there is a complete seal between the
front frame of the refrigerator and the top, sides and
bottom of the enclosure. A length of sealing strip is
applied to the rear surface of the front frame for this
purpose, see FIG. 4. The sealing should provide a
complete isolation of the appliance’s combustion system
from the vehicle interior.
NOTE: Be careful not to damage the sealing strip when
the refrigerator is put in place.

Securing the Refrigerator

After the refrigerator is put in place, (ensuring a combus-
tion seal at the front frame), the refrigerator is to be
secured in the enclosure with six screws. The screws
have to be installed in the following order:

Step 1: Two screws installed through the front base,
which includes the lower front strip installation.

The refrigerator is provided with a lower front strip (ship-
ped as a loose part). The front strip is to be installed after
the refrigerator is set into the cut-out opening.

1.

Install the lower front strip by sliding it under the
bottom hinge plates, as shown in FIG. 5.

FIG. 4

FIG. 5

5

Содержание RM 1272

Страница 1: ...1272 Automatic Energy Selector FOR YOUR SAFETY If you smell gas 1 Open windows 2 Don t touch electrical switches 3 Extinguish any open flame 4 Immediately call your gas supplier FOR YOUR SAFETY Do not...

Страница 2: ......

Страница 3: ...ector Button A AC Mode Indicator Lamp B AES AUTO Mode Indicator Lamp C GAS Mode Indicator Lamp D CHECK Indicator Lamp E Temperature Indicator Lamps F Climate Control Switch G Low Ambient Switch FIG 1...

Страница 4: ...efrigera tor compartment must be provided for ventilation of heavier than air fuel gases The lower vent of the recom mended kits is provided with proper size openings The flow of combustion and ventil...

Страница 5: ...and depth of the appliance NOTE A wood strip must be in place across the upper opening of the enclosure The top frame of the refriger ator will be anchored to the wood strip with screws see FIG 10 Th...

Страница 6: ...lled in the cut out opening of the base plate at the rear of the refrigerator The installer MUST make sure that the hose does not kink when run through the floor Seal around the hose that goes through...

Страница 7: ...ndenser at the back of the refrigerator VENTILATION HEIGHTS Installation with roof Minimum ventilation vent and lower side vent heights in Refrigerator Inches mm RM 1272 65 1651 CLEARANCES Minimum cle...

Страница 8: ...or several hours with the refrigerator operating the vehicle should be leveled to prevent this loss of cooling The vehicle needs to be leveled only so it is comfortable to live in no noticeable slopin...

Страница 9: ...amp C will illuminate Within 45 seconds the burner should be ignited and operating normally 2 On the initial refrigerator start up it may take longer than 45 seconds to allow air to be purged from the...

Страница 10: ...FF button 1 three or four times If repeated attempts fail to start the LP gas operation check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are ope...

Страница 11: ...normal setting usually about mid setting when the ice is formed Food in the fresh food compart ment may be frozen if the setting is left on COLDEST position DEFROSTING Shut off the refrigerator by pr...

Страница 12: ...with LP gas systems and refrigerators 1 REFRIGERATOR REMOVAL Before working on the refrigerator make sure the AC voltage andDCvoltageleadsare disconnected Shut off the gas supply Disconnect the gas s...

Страница 13: ...of flue tube Remove the burner jet Soak the jet in wood alcohol and blow it out with compressed air Re install and tighten burner jet NOTE The color of the flame shall be clear blue over the slots of...

Страница 14: ...k that the panel dimensions are in compliance with those given in the Table on this page and the instructions are read thoroughly When mounting the panel proceed as follows See figure page 15 A Open t...

Страница 15: ...2 5A Roof Base Roof Cover Lower Side Vent 3103633 xxx 3103634 xxx 3106666 xxx Power Vent Asm 3104131 002 Fill in xxx with color code numbers For color codes contact your supplier Alternate instruction...

Страница 16: ...MO FO 9819 16...

Отзывы: