column. The correct place to take the LP gas pres-
sure is at the test port just ahead of the burner jet.
(See FIG. 12).

E.

Inspect the flue baffle. It should be reasonably clean
and free of soot. Heavy soot formation indicates
improper functioning of the burner. The flue and
burner both require cleaning in the following manner:

1.

Unplug the refrigerator power cord from the 120 volt
AC outlet. (See FIG. 3).

2.

Disconnect or shut off the 12 volt power to the
refrigerator.

3.

Turn manual shutoff valve to OFF. (See FIG. 1).

4.

Remove cover from the burner housing. (See FIG.
1).

5.

Disconnect the wire from the high voltage electrode.

6.

Remove the burner mounting screws and remove the
burner assembly. (See FIG. 12).

7.

Remove the wire and the flue baffle from the top of
flue tube. Clean the flue from the top using a flue
brush. Blowing compressed air into the flue will not
properly clean soot and scale out of the flue tube.
Replace the flue baffle.

8.

Clean burner tube with a brush. Blow out burner with
compressed air.

9.

Before removing burner jet, clean burner area of soot
and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and blow it out with
compressed air. Re-install and tighten burner jet.
NOTE: The color of the flame shall be clear blue over
the slots of the burner. (See FIG. 13).

! WARNING 

DO NOT use a wire or pin when cleaning the burner
jet as damage can occur to the precision opening.
This can cause damage to the refrigerator or create
a fire hazard.

10. Reinstall burner, being careful that the end of the

burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube
and the thermocouple is positioned properly (tip of
thermocouple extends over two slots of burner).

11. Be sure to reconnect the wire to high voltage elec-

trode. Check the electrode for proper location and
gap. (See FIG. 14).

12. Turn on manual gas shutoff valve and check all

fittings for leaks.

13. Connect 120 volt power cord to the outlet and recon-

nect or turn on the 12 volt DC power.

14. Check LP gas safety shutoff. See page 6.

FIG. 14

Electrode

1/8" to 3/16"
(3-5 mm)

Burner tube

FIG. 13

Clear blue color
of flame

FIG. 12

BURNER JET

INLET FITTING

BURNER MOUNTING SCREWS

THERMOCOUPLE

SPARK
ELECTRODE

PRESSURE TEST PORT

MANUAL SHUT OFF VALVE
Shown in open position.

BURNER TUBE

SOLENOID VALVE

GAS EQUIPMENT ASSEMBLY

13

Содержание RM 1272

Страница 1: ...1272 Automatic Energy Selector FOR YOUR SAFETY If you smell gas 1 Open windows 2 Don t touch electrical switches 3 Extinguish any open flame 4 Immediately call your gas supplier FOR YOUR SAFETY Do not...

Страница 2: ......

Страница 3: ...ector Button A AC Mode Indicator Lamp B AES AUTO Mode Indicator Lamp C GAS Mode Indicator Lamp D CHECK Indicator Lamp E Temperature Indicator Lamps F Climate Control Switch G Low Ambient Switch FIG 1...

Страница 4: ...efrigera tor compartment must be provided for ventilation of heavier than air fuel gases The lower vent of the recom mended kits is provided with proper size openings The flow of combustion and ventil...

Страница 5: ...and depth of the appliance NOTE A wood strip must be in place across the upper opening of the enclosure The top frame of the refriger ator will be anchored to the wood strip with screws see FIG 10 Th...

Страница 6: ...lled in the cut out opening of the base plate at the rear of the refrigerator The installer MUST make sure that the hose does not kink when run through the floor Seal around the hose that goes through...

Страница 7: ...ndenser at the back of the refrigerator VENTILATION HEIGHTS Installation with roof Minimum ventilation vent and lower side vent heights in Refrigerator Inches mm RM 1272 65 1651 CLEARANCES Minimum cle...

Страница 8: ...or several hours with the refrigerator operating the vehicle should be leveled to prevent this loss of cooling The vehicle needs to be leveled only so it is comfortable to live in no noticeable slopin...

Страница 9: ...amp C will illuminate Within 45 seconds the burner should be ignited and operating normally 2 On the initial refrigerator start up it may take longer than 45 seconds to allow air to be purged from the...

Страница 10: ...FF button 1 three or four times If repeated attempts fail to start the LP gas operation check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are ope...

Страница 11: ...normal setting usually about mid setting when the ice is formed Food in the fresh food compart ment may be frozen if the setting is left on COLDEST position DEFROSTING Shut off the refrigerator by pr...

Страница 12: ...with LP gas systems and refrigerators 1 REFRIGERATOR REMOVAL Before working on the refrigerator make sure the AC voltage andDCvoltageleadsare disconnected Shut off the gas supply Disconnect the gas s...

Страница 13: ...of flue tube Remove the burner jet Soak the jet in wood alcohol and blow it out with compressed air Re install and tighten burner jet NOTE The color of the flame shall be clear blue over the slots of...

Страница 14: ...k that the panel dimensions are in compliance with those given in the Table on this page and the instructions are read thoroughly When mounting the panel proceed as follows See figure page 15 A Open t...

Страница 15: ...2 5A Roof Base Roof Cover Lower Side Vent 3103633 xxx 3103634 xxx 3106666 xxx Power Vent Asm 3104131 002 Fill in xxx with color code numbers For color codes contact your supplier Alternate instruction...

Страница 16: ...MO FO 9819 16...

Отзывы: