background image

INSTALLATION

GENERAL INSTRUCTION

This appliance is designed for storage of foods
and storage of frozen foods and making ice.
The refrigerators outlined herein have been design cer-
tified by A.G.A. under the ANSI Z21.19 Refrigerator
Standard for installation in a mobile home or recreational
vehicle and are approved by the Canadian Gas Asso-
ciation.
The certifications are, however contingent on the instal-
lation being made in accordance with the following in-
structions as applicable.
In the U.S.A., the installation must conform with:
1.

National Fuel Gas Code ANSI Z223.1-(latest edition)

2.

Manufactured Home Construction and Safety Stan-
dard, Title 24 CFR, Part 3280.

3.

Recreational Vehicles ANSI A119.2-(latest edition).

The unit must be electrically grounded in accordance
with the National Electric Code ANSI/NFPA 70-(latest
edition) when installed, if an external alternating current
electrical source is utilized.
4.

Any applicable local code.

In CANADA, the installation must conform with:
1.

Current CAN/CGA B149 Gas Installation Codes

2.

Current CSA Standard Z240.4 GAS-EQUIPPED
RECREATIONAL VEHICLES AND MOBILE HOUS-
ING.

3.

Where a flexible metal connector is used, it must
comply with the provisions of the current Standard
CAN1-6.10, METAL CONNECTORS FOR GAS
APPLIANCES.

4.

Any applicable local code

The unit must be electrically grounded in accordance
with the current CANADIAN ELECTRICAL CODE C22
Parts 1 and 2.

VENTILATION

The installation shall be made in such a manner as to
separate the combustion system from the living space
of the mobile home or recreational vehicle. Openings for
air supply or for venting of combustion products shall
have a minimum dimension of not less than 1/4 inch.

Proper installation requires one lower fresh air intake
and one upper exhaust vent. The ventilation kits shown
in this instruction manual have been certified for use with
the refrigerator models listed in the table. For "Certified
Vent System Kits
"  see page 15.  The ventilation kits
must be installed and used without modification. An
opening toward the outside at floor level in the refrigera-
tor compartment must be provided for ventilation of
heavier-than-air fuel gases. The lower vent of the recom-
mended kits is provided with proper size openings. The
flow of combustion and ventilating air must not be ob-
structed.
The lower side vent is fitted with a panel which provides
an adequate access opening for ready serviceability of
the burner and control manifold of the refrigerator.
This should be centered on the back of the refrigerator.

GAS CONNECTION

Hook-up to the gas supply line is accomplished at the
manual gas valve, which is furnished with a 3/8" SAE
(UNF 5/8" -18) male flare connection. All completed
connections should be checked for leaks with soapy
water.

! WARNING 

DO NOT use a flame to check for gas leaks.

The gas supply system must incorporate a pressure
regulator to maintain a supply pressure of not more than
11 inches water column.
When testing the gas supply system at test pressures in
excess of 1/2 psig, the refrigerator and its individual
shutoff valve must be disconnected from the gas supply
piping system.
When testing the gas supply system at pressures less
than or equal to 1/2 psig, the appliance must be isolated
from the gas supply piping system by closing its individ-
ual manual shutoff valve.
In case detailed instructions on the installation and
connection to the gas supply are required, contact your
dealer or distributor.

ELECTRICAL CONNECTION

120 Volts AC Connection

The refrigerator is equipped with a three-prong (ground-
ing) plug for your protection against shock hazards and
should be plugged directly into a properly grounded
three-prong receptacle. DO NOT cut or remove the
grounding prong from this plug. The free length of the
cord is 2 feet and therefore recommended that the
receptacle be located to the right side of the refrigerator
(viewed from the rear) and approximately 10 inches from
the floor (see FIG. 3). This allows easy access through
the vent door. The cord should be routed to avoid direct
contact with the burner cover, flue cover or any other
components that could damage the cord insulation.

12 Volts DC Connection

The refrigerator model RM 1272 require a continuous
12 volt DC supply (even though 2-way models are
designed to operate on 120 volts AC and gas, a 12 volt

FIG. 3

10"

120 Volt AC
receptacle

4

Содержание RM 1272

Страница 1: ...1272 Automatic Energy Selector FOR YOUR SAFETY If you smell gas 1 Open windows 2 Don t touch electrical switches 3 Extinguish any open flame 4 Immediately call your gas supplier FOR YOUR SAFETY Do not...

Страница 2: ......

Страница 3: ...ector Button A AC Mode Indicator Lamp B AES AUTO Mode Indicator Lamp C GAS Mode Indicator Lamp D CHECK Indicator Lamp E Temperature Indicator Lamps F Climate Control Switch G Low Ambient Switch FIG 1...

Страница 4: ...efrigera tor compartment must be provided for ventilation of heavier than air fuel gases The lower vent of the recom mended kits is provided with proper size openings The flow of combustion and ventil...

Страница 5: ...and depth of the appliance NOTE A wood strip must be in place across the upper opening of the enclosure The top frame of the refriger ator will be anchored to the wood strip with screws see FIG 10 Th...

Страница 6: ...lled in the cut out opening of the base plate at the rear of the refrigerator The installer MUST make sure that the hose does not kink when run through the floor Seal around the hose that goes through...

Страница 7: ...ndenser at the back of the refrigerator VENTILATION HEIGHTS Installation with roof Minimum ventilation vent and lower side vent heights in Refrigerator Inches mm RM 1272 65 1651 CLEARANCES Minimum cle...

Страница 8: ...or several hours with the refrigerator operating the vehicle should be leveled to prevent this loss of cooling The vehicle needs to be leveled only so it is comfortable to live in no noticeable slopin...

Страница 9: ...amp C will illuminate Within 45 seconds the burner should be ignited and operating normally 2 On the initial refrigerator start up it may take longer than 45 seconds to allow air to be purged from the...

Страница 10: ...FF button 1 three or four times If repeated attempts fail to start the LP gas operation check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are ope...

Страница 11: ...normal setting usually about mid setting when the ice is formed Food in the fresh food compart ment may be frozen if the setting is left on COLDEST position DEFROSTING Shut off the refrigerator by pr...

Страница 12: ...with LP gas systems and refrigerators 1 REFRIGERATOR REMOVAL Before working on the refrigerator make sure the AC voltage andDCvoltageleadsare disconnected Shut off the gas supply Disconnect the gas s...

Страница 13: ...of flue tube Remove the burner jet Soak the jet in wood alcohol and blow it out with compressed air Re install and tighten burner jet NOTE The color of the flame shall be clear blue over the slots of...

Страница 14: ...k that the panel dimensions are in compliance with those given in the Table on this page and the instructions are read thoroughly When mounting the panel proceed as follows See figure page 15 A Open t...

Страница 15: ...2 5A Roof Base Roof Cover Lower Side Vent 3103633 xxx 3103634 xxx 3106666 xxx Power Vent Asm 3104131 002 Fill in xxx with color code numbers For color codes contact your supplier Alternate instruction...

Страница 16: ...MO FO 9819 16...

Отзывы: