38
is the gas cylinder or pressure regulating valve open?
does the liquid gas cylinder still contain gas? If no liquid movement is evident on sha-
king the cylinder, then the gas cylinder is empty.
are several operating methods being used simultaneously?
have warm foodstuffs been stored in the cooler?
was too large a quantity of food or drink stored at any one time? Food and drink should
be stored as to allow free air circulation. Do not use paper or plastic plates. Always
keep containers for liquids sealed.
When contacting our customer service department, please indicate the unit type, product
number, serial number and type of defect.
We accept responsibility for the perfect condition of the unit, the guarantee being in
accord-ance with our guarantee conditions.
19. Technical data
Model:
RC1500
Gas operation
butane
(propane):
Nominal heating Qn:
112 W - 10.1 g/h
(118 W - 8.4 g/h)
Minimal heating Qn min:
91 W - 6.6 g/h
(80 W - 5.7 g/h)
Gas pressure p:
28-30/37 mbar
Jet size No. 19
Category:
N
Climate pass:
GB - l
3
+
IE - l
3
+
Permitted excess operating pressure:
30 bar
Electric operation:
220 - 240 V AC 50/60Hz
65 W
12 V DC
65 W
24 V DC
55 W
Capacity:
21 L
Refrigerant:
0.24 kg NH
3
+ H
2
O
The appliance does not contain any CFCs/HCFCs.
Sodium chromate is used for corrosion protection (less than 2 weight % of the coolant).
GB
This appliance complies with the following EEC directives:
LVD-Directive
73/23/EEC with amendment
90/683/EEC
EMC-Directive
89/336/EEC
Gas-Directive
90/396/EEC.