EN
Operating
MCS T6, MCS T12, MCS T16
8
6.2
Dual Button Functions
Up and Down Buttons
•
While in the On Mode:
Simultaneously press the Up and Down Buttons to dis-
play outside air temperature providing the optional outside air temperature sen-
sor is installed.
•
While in the Program Mode:
Simultaneously press the Up and Down Buttons
to set new program defaults.
Power and Down Buttons
•
While viewing the service fault history log:
Simultaneously press the Power
and Down Buttons to clear the fault history log (see “Service History Log” on
page 14).
•
While in the On Mode:
Simultaneously press the Power and Down Buttons to
enter the Dehumidification Mode (see “Dehumidification Mode” on page 11).
7
Operating
7.1
Initial startup
A
➤
Ensure seawater intake ball valve (seacock) is open.
➤
Turn on air conditioner circuit breaker.
➤
If the seawater pump has its own circuit breaker, turn that on.
➤
Press the Fan Button (fig.
1
2, page 3).
✓
This energizes the fan.
➤
Verify that the fan is running and that there is steady airflow out of the supply-air
grille.
➤
Select a temperature set point lower than the current cabin temperature.
✓
This starts the compressor and seawater pump.
NOTICE!
Do not turn the unit off and immediately turn it back on. Allow at least
30 s for refrigerant pressure equalization.
MCS-6-12-16--O-West.book Seite 8 Dienstag, 14. November 2017 11:28 11