EN
Programming
MCS T6, MCS T12, MCS T16
18
P-9
High Water Temperature
Limit (°F)
OFF
100 – 150
P-10
Display Brightness
Control
9
4
= Low
13
= Maximum
P-11
Display
º
F or
º
C
F
F
= Fahrenheit displayed
C
= Celsius displayed
P-12
Cycle Pump With
Compressor or
Continuous Pump
OFF
OFF
= Cycle with compressor
On
= Continuous pump
P-13
Reverse Fan Speeds Dur-
ing Heating Mode
rEF
nor
= Normal fan operation
rEF
= Reversed fan in heating
P-14
Continuous Fan or Cycle
Fan with Compressor
con
CYC
= Cycle fan with compressor
con
= Continuous fan operation
P-15
Reverse Cycle Heating or
Electric Heat Only Option
Installed (cooling only
units)
nor
nor
= Reverse cycle heating
ELE
= Electric heater installed
P-16
Fan Motor type selection
Shaded Pole or Split
Capacitor.
SC
SP
= Shaded pole fan motor
SC
= Split capacitor fan motor
P-17
Reset Memorized
Programming Defaults
nor
rSt
= Reset defaults
nor
= Normal
P-18
Reserved for Future
Option
–
–
P-19
Reserved for Future
Option
–
–
P-20
Filter Threshold
(x10 hours)
00
00 – 250
P-21
Current Filter Time
(x10 hours)
x10 Hours Using
Current Filter
–
P-22
Voltage Calibration (Volts)
AC Voltage
–
Program
number
Description
Default Range
MCS-6-12-16--O-West.book Seite 18 Dienstag, 14. November 2017 11:28 11