background image

6

LA-03 MODEL AWNING INSTALLATION INSTRUCTIONS

c.

Install a recessed AC outlet box (FS type outside water
tight, not supplied). The electrical outlet box cover must
be flush with the side wall of the coach. It must be a
minimum of 1-1/8"  away from the  RH end plate, but not
more than 1-1/4" maximum. It must be 3-1/8 " down from
the top of the awning case. See FIG. 9 & 9A.

Note: This placing will allow the 3308645.XXX Decorative End
Cap Kit to be installed over the outlet box.
d.

Route a 14 AWG 3 conductor w/ground copper Romex
wire (not supplied) between the outlet box on the awning
control box and the outlet box next to the right hand end
of the awning. Secure at both outlet boxes using Romex
connectors (not supplied), leaving  8 inches of wire
extended. See FIG. 9.

e.

Drill a 0.750” diameter hole in the center of the outside
outlet box cover and install the water tight pigtail wire
harness female receptacle plug. Connect the 4 wires
from the pigtail harness to the 3 conductor w/ground
Romex wires in the outlet box with wire nuts (Black -
Black, White - White, Red - Red, & Green, Green w/
yellow stripe - bare copper or Ground) and tape the
connections.

FIG. 9

AC Breaker
Box *

Control Box &
Junction Box

Outdoor Rated Outlet Box
Recessed Into Wall *

AC Supply
Line *

Outlet Box With
GFI Receptacle *

14 AWG 3 Conductor
W/Ground Romex *

Awning Motor
Lead With 6”
Drip Loop

Awning

Control Box
6’ Power Cord

Wind Sensor

Wind Sensor
Cable*

Align Key On
Motor Lead
With Slot On
Receptacle

Battery *

Brown Wire *
- 12VDC

Pink Wire *
+12VDC

Remote
Switch

Ignition
Switch*

Yellow
Brown
Green
Wires *

* Designates
Installer Supplied

f.

Place the cover with the connector plug and gasket on
the junction box and tighten the screws.

g.

The awning motor cable is to be connected to  the cover
receptacle on the junction box cover. Be sure to form a

3/16"

1/8"

3"

Awning
Case

Use Mounting Bracket as
Template, Mark and Drill 3
Pilot Holes, Fill Holes with
Silicon Sealant

FIG. 9A

Outlet Box

Содержание LA-03

Страница 1: ...d before installation adjust ment service ormaintenanceisper formed This unit must be installed by a qualified service technician Modification of this product can be extremely hazardous and could re s...

Страница 2: ...ningisfactorypresetwitha20 slope Approvalisrequired from Dometic for alternate mounting brackets supplied by the coach manufacture and for mounting of the LA 03 awning on coaches with curved side wall...

Страница 3: ...ch directly behind the lateral arm shoulders The awning is required to be mounted a minimum of 8 feet 2 4 meters abovetheground CSA C22no 236latestedition a The awning requires 10 verticle inches of c...

Страница 4: ...r GFI Ground Fault Interrupter receptacle not supplied within reach of the 6 power cord of the awning control box See FIG 9 e Install a recessed AC outlet box FS type outside water tight notsupplied t...

Страница 5: ...e Tuck gasket down into its final position in gap between the side wall and back of awning case 7 INSTALLATIONOFCONTROLBOX Disconnect 115 volt AC Failure to follow these instructions could create a sh...

Страница 6: ...arness female receptacle plug Connect the 4 wires from the pigtail harness to the 3 conductor w ground Romex wires in the outlet box with wire nuts Black Black White White Red Red Green Green w yellow...

Страница 7: ...not intended for cold weather operation Awningwillcloseatapproximately30 F with sensor turned ON Note If the awning is open with the wind sensor ON and the wind sensor is unplugged for any reason the...

Страница 8: ...ect the Pink wire to the Positive DC source of the ignition system battery d Connect the Brown wire to the Brown pigtail wire off the control box e Connect the Brown wire to the Negative DC source of...

Страница 9: ...Note The left limit adjustment is above the lip on the front cover and hard to locate 3 Continue to adjust until the lateral arm elbow joint is 1 4 gap from its stop point See FIG 18 b Awning Over Ext...

Страница 10: ...uctor Cable to Wind Sensor Green Brown Yellow Pink Green Yellow Brown A E Systems A E Systems WIND SENSOR WIND SENSOR ON OFF RESET CIRCUIT RESET CIRCUIT LA 03 Green Yellow Stripe To Motor Red To Motor...