background image

3

LA-03 MODEL AWNING INSTALLATION INSTRUCTIONS

(1) Sensor Wind
(1) Crank, Hand

Required parts installer supplied

(3) Screws, #10 Stainless

Plate, Backup (See specification chart)

(1) Cable, Flat 4 Conductor-Max. 18'
(2) RJ-11 Terminal
(1) Box, Outlet Type FS-Outdoor
(2) Connector, Romex
(1) Cover, Type FS Water Tight
(1) Tube, Silicone Sealant
(1) Wire, 14 AWG Copper 3 Wire W/Ground
(8) Wire Nuts & Splice Connectors

 Tape, Electrical

(1) GFI Receptacle
(1) Misc. 18 AWG DC Wires

3.

MOUNTING REQUIREMENTS

The mounting bracket plates are to be placed on the outside
of the coach directly behind the lateral arm shoulders. The
awning is required to be mounted a minimum of 8 feet (2.4
meters) above the ground (CSA-C22 no. 236 latest edition).
a.

The awning requires 10 verticle inches of clear unob-
structed surface along its entire length for installation.
See FIG. 1. The awning must have enough clearance
above a door to prevent damage to the fabric or door. The
distance is determined by the projection of the door. See
FIG. 2 and Section 8.

FIG. 1

A

B

C

“A” Door Projection

24”

30”

36” 48”

“B” Mounting Height

9.5”

12”

14” 18.5”

“C” Angle Of Slope

20°

20°

20° 20°

FIG. 2

FIG. 3

A

B

C

L

18’/216”

20”

NA

214”

20’/240”

20”

NA

238”

22’/264”

20”

150”

262”

24’/288”

20”

162”

286”

MOUNTING BRACKET LOCATION

L = Awning

Length

A

B

C

Awning
Requires 10”
of Clearance

Coach
Sidewall

Содержание LA-03

Страница 1: ...d before installation adjust ment service ormaintenanceisper formed This unit must be installed by a qualified service technician Modification of this product can be extremely hazardous and could re s...

Страница 2: ...ningisfactorypresetwitha20 slope Approvalisrequired from Dometic for alternate mounting brackets supplied by the coach manufacture and for mounting of the LA 03 awning on coaches with curved side wall...

Страница 3: ...ch directly behind the lateral arm shoulders The awning is required to be mounted a minimum of 8 feet 2 4 meters abovetheground CSA C22no 236latestedition a The awning requires 10 verticle inches of c...

Страница 4: ...r GFI Ground Fault Interrupter receptacle not supplied within reach of the 6 power cord of the awning control box See FIG 9 e Install a recessed AC outlet box FS type outside water tight notsupplied t...

Страница 5: ...e Tuck gasket down into its final position in gap between the side wall and back of awning case 7 INSTALLATIONOFCONTROLBOX Disconnect 115 volt AC Failure to follow these instructions could create a sh...

Страница 6: ...arness female receptacle plug Connect the 4 wires from the pigtail harness to the 3 conductor w ground Romex wires in the outlet box with wire nuts Black Black White White Red Red Green Green w yellow...

Страница 7: ...not intended for cold weather operation Awningwillcloseatapproximately30 F with sensor turned ON Note If the awning is open with the wind sensor ON and the wind sensor is unplugged for any reason the...

Страница 8: ...ect the Pink wire to the Positive DC source of the ignition system battery d Connect the Brown wire to the Brown pigtail wire off the control box e Connect the Brown wire to the Negative DC source of...

Страница 9: ...Note The left limit adjustment is above the lip on the front cover and hard to locate 3 Continue to adjust until the lateral arm elbow joint is 1 4 gap from its stop point See FIG 18 b Awning Over Ext...

Страница 10: ...uctor Cable to Wind Sensor Green Brown Yellow Pink Green Yellow Brown A E Systems A E Systems WIND SENSOR WIND SENSOR ON OFF RESET CIRCUIT RESET CIRCUIT LA 03 Green Yellow Stripe To Motor Red To Motor...

Отзывы: