EN
Installation
Skysol Powered Roofblind
24
1. Align the blind with the window cut-out and mark where the holes are to be
drilled for the frame.
2. Ensure the frame is square within the recess by using a measuring device.
Measure the outside corner of the frame to the opposite outside corner and
repeat for the other two corners. These measurement should be within
3 mm of each other.
3. Fix the frame with the screws to the ceiling (
2.
).
If packing of tracks is required do not fully tighten the screws before packers
are in place as this can cause damage to the tracks (fig.
It might be easier to loosely fit the four corner screws (
1.
) first to position and
hold the blind while the main fixings (
3.
) are fitted.
If fitting a curved frame position the blind vertically using the side track
screws rather than the corner screws.
7.3.3
Connecting the motor
➤
Connect the motor as shown:
–
Dometic radio controlled blind internal receiver (fig.
–
Dometic radio controlled blind external receiver (fig.
–
–
Somfy radio controlled blind external receiver (fig.
–
Somfy radio controlled blind internal receiver (fig.
7.3.4
Moving rail fitting
➤
Dependent on the version the blind is equipped with one or two moving
rails.
7.3.5
Blind panel fitting
A
Before fitting the blind panel proceed as follows:
1. Connect the power and drive the moving rail away from the head rail before
you start fitting the panels (fig.
1.
). There is not enough
space to fit the panels with the shoes in the shipped position.
2. Check whether the moving rail is square and moves freely before fitting any
of the other panels. If the moving rail is not square it can be adjusted as
shown (fig.
NOTICE! Risk of damage
Ensure that the cording on each panel is routed correctly (fig.
Always extend the fabric panels completely before clipping them in. This pulls
the cords tight and prevents them from dropping and potentially getting
trapped when being clipped in.
Содержание 9600023490
Страница 3: ...3 Skysol Powered Roofblind 1 2 3 4 7 3 13 5 6 8 9 10 12 11 1 24 V 12 V 2x 2 ...
Страница 4: ...Skysol Powered Roofblind 4 3 mm 3 mm 3 4x 6 10x 1 1 3 1 1 2 max 6 mm 4 ...
Страница 5: ...5 Skysol Powered Roofblind 2 1 2 2 3 1 1 5 4x 6 10x 1 1 3 1 1 2 max 6 mm 6 ...
Страница 8: ...Skysol Powered Roofblind 8 1 2 3 b 4 3 1 2 7 6 5 c ...
Страница 9: ...9 Skysol Powered Roofblind d 2x 2 1 3 4 e ...
Страница 10: ...Skysol Powered Roofblind 10 2 3 5 6 1 4 f 2 1 3 g ...
Страница 11: ...11 Skysol Powered Roofblind 2 3 1 h 1 3 5 2 4 i ...
Страница 12: ...Skysol Powered Roofblind 12 2 1 4 3 5 j ...