It is highly recommended that a set of safety infra-red beams be used in conjunction with this product. The safety beams must be installed in such a way that 
the product is prevented from running when anything is in the path of the door or gate. 

7.

 

Over and above the recommendation to use safety infra-red beams with this product it is mandatory to install and use a safety beam set when using the 
automatic closing feature. It is recommended that a warning light be fitted to any automation system. 

 

After Installation: It Is The Responsibility Of The Installer To Ensure The User: 

 

1.

 

Is proficient in the use of the manual emergency release mechanism.  

2.

 

Is issued with the documentation accompanying this product. 

3.

 

Understands that the gate or door may not be operated out of clear sight. 

4.

 

Ensures that children are kept clear of the gate or door area at all times, and that children do not play with the remote transmitters or any fixed trigger switches 
linked to the system.  

5.

 

Is instructed not to attempt to repair or adjust the automation system and to be aware of the danger of continuing to use the automation system in an unsafe 
condition before a service provider attends to it. 

6.

 

Is proficient in testing the unit’s safety obstruction sensing system. 

7.

 

Is aware of what to check for with regards to wear and tear that may need to be attended to from time to time by the service provider.   

8.

 

Is aware that a fatigued battery may not be disposed of in the general refuse and must be handed in at a battery merchant for safe disposal. Before removing 
the battery from the system the household mains must be disconnected. In the case of the motor unit being removed and scrapped, the battery must be 
removed first.

 

 

0011014.005 

 

 

* Based on the assumption that the door is balanced correctly and moving freely. 

 

 

 

 

 

TECHNICAL SPECIFICATIONS 

Model 

DC BLUE  ADVANCED Pico 

DC BLUE  ADVANCED 

Primary power supply 

220 – 240Vac @ 50hz 

220 – 240Vac @ 50hz 

Peak power consumption 

100W peak @ (220 -240vac) 

120W peak @ (220 -240vac) 

Motor voltage 

24Vdc 

24Vdc 

Maximum operations per day* 

50 full cycles per 24hrs @ a rate of Max. 5 
per hour 

50 full cycles per 24hrs @ a rate of Max. 5 per 
hour 

Traveller speed* 

8m/min 

8m/min 

Operating temperature  range  -10 to 50° C (14F to 122F) 

-10 to 50° C (14F to 122F) 

Anti-crushing safety sensing 

Yes - Electronic digital profiling 

Yes - Electronic digital profiling 

Auxiliary supply output 

24Vdc @ 250mA peak or 150mA continuous  24Vdc @ 250mA peak or 150mA continuous 

Rated battery charging voltage  27.5Vdc 

27.5Vdc 

Built in receiver  format 

ET BLU MIX © enhanced rolling code. 

ET BLU MIX © enhanced rolling code. 

Receiver frequency 

433.92Mhz 

433.92Mhz 

Memory 

EEPROM 

EEPROM 

Applicable door types 

One piece trackless tip-up or multiple panel 

sectional overhead  single width doors 

One piece trackless tip-up or multiple panel 

sectional overhead double width doors 

Drawbar options(Ex-stock) 

2.2m  or 3.2m 

2.2m or 3.2m or 3.7m 

Applicable door sizes* 

<10m² 

<15m² 

Содержание DC Blue Advanced

Страница 1: ...ET DC BLUE ADVANCED USER 2013 012 24 11 2016 1 www et co za Domestic garage door operators User Instructions...

Страница 2: ...spected as a hazard if not used correctly Page CATEGORY INTRODUCTION 3 Safety obligationsand general warnings 4 Technical Specifications 5 Control panel dashboard 6 Component identification and descri...

Страница 3: ...edoor ina garage door system aresound and strong enough to allowproperfixing ofthe operator 6 It is the responsibility of theinstaller toensure theinstalled position selected for this product falls wi...

Страница 4: ...eed to be attended to from time to time by the service provider 8 Is awarethata fatiguedbatterymaynot bedisposed ofin the generalrefuseand mustbe handed inata battery merchantfor safe disposal Before...

Страница 5: ...ET DC BLUE ADVANCED USER 2013 012 24 11 2016 5 www et co za CONTROL PANEL DASHBOARD TOP BOTTOM...

Страница 6: ...ET DC BLUE ADVANCED USER 2013 012 24 11 2016 6 www et co za COMPONENT IDENTIFICATION AND DESCRIPTIONS...

Страница 7: ...the operator reverts to standby mode On the next BT button trigger the motor will begin the door closing NB The safety sensing overload system needs to be tested at least once a month As prescribed b...

Страница 8: ...dwired trigger Door begins opening and courtesy light switches on Wait for door to reach the full open position Door stops and waits in the open position Courtesy light remains on for a further 3 minu...

Страница 9: ...release either the remote button trigger or the hardwired trigger before the door reaches the full open position Door stops and waits for next instruction Courtesy light remains on for a further 3 min...

Страница 10: ...n Stop door while opening or simply wait until it reaches the open position Door stops and waits at the required open position Courtesy lightremains on for a further 3 minutes Press and hold the remot...

Страница 11: ...on Whilstbuzzer is still sounding Press and release the remote trigger button to activate Holiday lock out Buzzer beeps light flashes rapidly and display shows H to indicate Holiday lock out is active...

Страница 12: ...buzzer flashes and sounds three times before door begins closing automatically ADVANCED FEATURES Safety beam input NB This input only affects the closing cycle Action Response Door closing Light on In...

Страница 13: ...any BT transaction when the household mains power is off Action Response Every operation of the door from any position Light will come on for 3 minutes and door operates If the light is off and the L...

Страница 14: ...display shows b Buzzer beeps once and display shows b Press and hold required remote button LED on remote transmitter remains lit Press and release the SET button 1 on display and 1 beep user code su...

Страница 15: ...ive Page 10 Household mains power failure Operating on battery power only Re connect household mains supply To test Check that light switches on when operating door Page 13 Door stops Motor fuse blown...

Страница 16: ...application or use of the product other than the intended use and application described in the product documentation 4 Any application and or usage of this product outside of the technical specificati...