CT100G Series Inverter
CHAPTER 4 FUNCTION PARAMETER TABLE
- 52 -
Functio
n code
Name
Detailed instruction of parameters
Default
value
Attrib
ution
F12.03
Response delay
0ms
~
20ms
2
○
F12.04
Communication timeout
detection time
0.0
(
invalid
),
0.1s
~
60.0s
0.0
○
F12.05
Data transfer format selection
Unit position: not standard MODBUS-RTU
protocol
0:not standard MODBUS-RTU protocol
1:standard MODBUS-RTU protocol
Ten position:reserved
31
○
F12.06
Communication read current
resolution
0:0.01A
1:0.1A
0
○
F12.07 reserve
F13 Group
Auxiliary function
F13.00
Jogging frequency
0.00Hz
~
max frequencyF00.06
2.00
○
F13.01
Jogging running ACC time
0.0s
~
6500.0s
20.0
○
F13.02
Jogging running DEC time
0.0s
~
6500.0s
20.0
○
F13.03
ACC time 2
0.0s
~
6500.0s
20.0
○
F13.04
DEC time 2
0.0s
~
6500.0s
20.0
○
F13.05
ACC time 3
0.0s
~
6500.0s
20.0
○
F13.06
DEC time 3
0.0s
~
6500.0s
20.0
○
F13.07
ACC time 4
0.0s
~
6500.0s
20.0
○
F13.08
DEC time 4
0.0s
~
6500.0s
20.0
○
F13.09
Jump frequency 1
0.00Hz
~
Max. Frequency F00.06
0.00
○
F13.10
Jump frequency 2
0.00Hz
~
Max. Frequency F00.06
0.00
○
F13.11
Jump frequency range
0.00Hz
~
Max. Frequency F00.06
0.00
○
F13.12
REV control
0:permit REV 1: forbid REV
0
○
F13.13
Droop control
Slip when the torque current is equal to the
rated current of the motor
0.00Hz
~
10.00Hz
0.00
○
F13.14
Set power on arrive time
0h
~
65535h
0
○
F13.15
Set running arrive time
0h
~
65535h
0
○
F13.16
Protection selection
0:not protect
1:protect
0
○
F13.17
Frequency detection value
(FDT1)
0.00Hz
~
max frequency F00.06
50.00
○
F13.18
Frequency detection delay
value (FDT1)
0.0%
~
100.0%
(
FDT1 level
)
5.0
○
F13.19
Frequency arrival detection
amplitude
0.0
~
100.0% (Max. frequency)
0.0
○
F13.20
Jump frequency valid or not
while ACC/DEC
0:invalid
1:valid
0
○
F13.21
Running time arrive action
0:keep running
1: alarm fault
0
○
F13.22
Power on time arrive action
0:keep running
1: alarm fault
0
○
F13.23
Switch frequency of ACC time
1/2
0.00Hz
~
Max. Frequency F00.06
0.00
○
F13.24
Switch frequency of DEC time
1/2
0.00Hz
~
Max. Frequency F00.06
0.00
○
F13.25
Terminal JOG priority
0:invalid
1:valid
0
○