CT100G Series Inverter
CHAPTER 4 FUNCTION PARAMETER TABLE
- 42 -
Functio
n code
Name
Detailed instruction of parameters
Default
value
Attrib
ution
Ten thousand place:
reserve
F07 Group
Output terminals
F07.00
HDO output mode
0:pulse output
1:switch output
0
○
F07.01
HDO switch output selection
0: no output
1: running
2: fault output
3: frequency level detection FDT1 output
4: frequency arrival
5: zero speed running 1 (no output at
stop)
6: motor over load pre-alarm
7: inverter over load pre-alarm
8: set count value arrival
9: specified count value arrival
10:length arrival
11:simple PLC cycle is completed
12:running time arrival
13: frequency is limited
14: torque is limited
15: ready to run
16:AI1>AI2
17:upper limit frequency arrival
18:lower limit frequency arrival
(
related to
running
)
19:under voltage state output
20: communication set
21:location finished
(
reserved
)
22:location approach
(
reserved
)
23:zero speed running 2 ( output at stop)
24:power on time arrive
25:frequency level detection FDT2 output
26:frequency arrive 1 output
27: frequency arrive 2 output
28: current arrive 1 output
29: current arrive 2 output
30: time arrive output
31: AI1 input out of limit
32: loss load
33: REV running
34: 0 current state
35: module temperature arrive
36: output current over limit
37: lower frequency arrive (not related to
running)
38: fault output (all faults)
39: motor over heat pre-alarm
40: current running time arrive
41: fault output ( free stop faults and not
output under voltage
0
○
F07.02
Relay T1 output selection
2
○
F07.03
Relay T2 output selection
0
○
F07.04
D0 output selection
1
○
F07.05 reserve
reserve
4
○
F07.06
HDO pulse output selection
0: running frequency
0
○