CT100G Series Inverter
CHAPTER 4 FUNCTION PARAMETER TABLE
- 51 -
Functio
n code
Name
Detailed instruction of parameters
Default
value
Attrib
ution
F11.36
Step 9 running time
0.0s (h)
~
6553.5s (h)
0
○
F11.37
PLC step 9 ACC/DEC time
selection
0
~
3
0
○
F11.38
Step 10 running time
0.0s (h)
~
6553.5s (h)
0
○
F11.39
PLC step 10 ACC/DEC time
selection
0
~
3
0
○
F11.40
Step 11 running time
0.0s (h)
~
6553.5s (h)
0
○
F11.41
PLC step 11 ACC/DEC time
selection
0
~
3
0
○
F11.42
Step 12 running time
0.0s (h)
~
6553.5s (h)
0
○
F11.43
PLC step 12 ACC/DEC time
selection
0
~
3
0
○
F11.44
Step 13 running time
0.0s (h)
~
6553.5s (h)
0
○
F11.45
PLC step 13 ACC/DEC time
selection
0
~
3
0
○
F11.46
Step 14 running time
0.0s (h)
~
6553.5s (h)
0
○
F11.47
PLC step 14 ACC/DEC time
selection
0
~
3
0
○
F11.48
Step 15 running time
0.0s (h)
~
6553.5s (h)
0
○
F11.49
PLC step 15 ACC/DEC time
selection
0
~
3
0
○
F11.50
PLC running time unit
0:s
1:h
0
○
F11.51
Multi-step 0 give command
mode
0:F11.00
1:AI1
2:AI2
3:
reserve
4:high speed pulse
5:PID
6:F00.09 give
,
UP/DOWN can
changeUP/DOWNmodify
0
○
F12 Group 485 communication
F12.00
Local address
1
~
247
,
0 broadcast address
1
○
F12.01
Baud rate
Unit place:
MODBUS
0:300BPS
1:600BPS
2:1200BPS
3:2400BPS
4:4800BPS
5:9600BPS
6:19200BPS
7:38400BPS
8:57600BPS
9:115200BPS
Ten place:reserved
Hundred place:reserved
Thousand place:reserved
5006
○
F12.02
Data check
0: no check
(
8-N-2
)
1:even check
(
8-E-1
)
2:odd check
(
8-O-1
)
3:8-N-1
1
○