3.3.2
ZGP commissioning telegram
ZGP commissioning telegrams are used to commission PTM 216Z into ZGP networks. ZGP
commissioning telegrams are identified by the Command ID 0xE0. The following 31 byte of
data identify the properties of PTM 216Z:
Device type:
0x07 (Generic Switch)
Options:
0x85
Extended Options:
0xF2
Security key
16 byte device-unique security key
Security key hash
4 byte hash of the key for validation
Outgoing security counter
4 byte value of security counter
Options
0x10 (Switch information present)
Switch Info
0x02 = 2 byte of information follow
Generic Switch Configuration
0x05 = 5 buttons
Current Contact
Button that was pressed (see Figure 7)
Figure 8 below shows the payload structure for ZGP commissioning telegrams used by PTM
216Z.
Figure 8 – ZGP payload structure for commissioning telegrams