background image

5

11.01.16 en / 627

The menu for relay 2 is identically

  Operating – Input-menu for relay 1

Umin [V]

Umax [V]

Asym [%]

Asym [%]

<I [A]

tv 1

A / R

Phseq

Sp 1

>I [A]

<CosP

<P [W]

<S [W]

<Q [var]

<f [Hz]

<P [W]

<S [W]

<Q [var]

<f [Hz]

>P [W]

>S [W]

>Q [var]

>f [Hz]

Hyst

>P [W]

>S [W]

>Q [var]

>f [Hz]

Hyst

<CosP

>CosP

>CosP

>I [A]

<I [A]

Umin [V]

tv 1

A / R

Pheq

Sp 1

Umin [V]

Umax [V]

Umin [V]

tv 1

A / R

Pheq

Sp 1

R1

R1

R1

R1

R2

R2

R2

R2

Esc

Esc

Esc

Esc

Esc

Esc

Esc

Esc

Esc

Esc

actual

value

actual

value

actual

value

actual

value

actual

value

actual

value

actual

value

actual

value

440

10,0

ON

ON

440

440

100

12,00

440

10,0

ON

ON

440

0

0

OFF

OFF

0

0

0

0

0

0

OFF

OFF

0

Esc (Break) 3s

Esc 3s

Break (cancel changes)

OK (store settings)

OK (return with new setting)

(OK) 3s

(OK)

RUN

Display

mode

Rel1

Rel2

Ta

Esc

Содержание VARIMETER PRO

Страница 1: ...ng of portable equipment Motor protection on Phase failure Transformer protection on asymmetric load Frequency monitoring on inverter outputs 0268581 More Information MK 9300N The MK9300N has 1 relay...

Страница 2: ...RUN mode and continuously measures the actual values The buttons and toggle between the different values Pressing Esc for more than 3 sec starts the input mode One or more measuring values can be ass...

Страница 3: ...mode Scrolls the display to show one of the 10 possible values If a values exceeds the setting the values is indicated flashing on inverted display In the case of a fault display the display always r...

Страница 4: ...t changes to input mode In input mode the measurement is disabled the relays are in failure mode and the indicator LED is orange With the buttons the different setting values can be chosen Move cursor...

Страница 5: ...A Umin V tv 1 A R Pheq Sp 1 Umin V Umax V Umin V tv 1 A R Pheq Sp 1 R1 R1 R1 R1 R2 R2 R2 R2 Esc Esc Esc Esc Esc Esc Esc Esc Esc Esc actual value actual value actual value actual value actual value act...

Страница 6: ...rating Setting valid for both relays Start up delay ta 0 10 s in steps of 0 1 s Current Measuring Input i k Nominal current AC 12 A Measuring range AC 100 mA 12 A Max overload continuously 16 A short...

Страница 7: ...IN EN 60 529 Terminals IP 20 DIN EN 60 529 Housing thermoplastic with VO behaviour according to UL Subject 94 Vibration resistance Amplitude 0 35 mm frequency 10 55 Hz Climate resistance 20 060 04 EN...

Страница 8: ...s voltage Electric shock will result in death or serious injury Disconnect all power supplies before servicing equipment Faults must only be removed when the relay is disconnected The user has to make...

Отзывы: