background image

7

11.01.16 en / 627

  Technical Data

 

Standard Types

MK 9300N.11/022   3 AC 20 ... 440 V   AC 12 A   DC 24 V
Article number: 

0063630

  Measuring voltage: 

3 AC 20 ... 440 V

  Measuring current: 

AC 12 A

  Auxiliary voltage U

H

DC 24 V

  Output: 

1 changeover contact

  Width: 

22,5 mm

MH 9300.12/022   3 AC 20 ... 440 V   AC 12 A   AC 230 V
Article number: 

0063631

  Measuring voltage: 

3 AC 20 ... 440 V

  Measuring current: 

AC 12 A

  Auxiliary voltage U

H

AC 230 V

  Output: 

1 changeover contact (Rel1) and

   

1 changeover contact (Rel2)

  Width: 

45 mm

Output Circuit (Rel1: 11/12/14; Rel2: 21/22/24)

Contacts:   

 

MK 9300N: 

1 changeover contact

MH 9300: 

1 changeover contact (Rel1) and 

 

1 changeover contact (Rel2)

Thermal current I

 th

:

 

2 x 4 A

Switching capacity 

to AC 15: 
NO contacts: 

3 A / AC 230 V          IEC/EN 60 947-5-1

NC contacts: 

1 A / AC 230 V          IEC/EN 60 947-5-1

to DC 13 
NO contacts: 

1 A / DC 24 V          IEC/EN 60 947-5-1

NC contacts: 

1 A / DC 24 V          IEC/EN 60 947-5-1

Electrical life

  

to AC 15 at 3 A, AC 230 V: 

 2 x 10

5

 switch. cycl.  IEC/EN 60 947-5-1

Permissible switching 
frequency:

 

1800 / h

short circuit strength
Max. fuse rating:

 

4 A gl                         

 DIN VDE 0660

Mechanical life

30 x 10

6

 switching cycles

General Data

Nominal operating mode:

 

continuous operation

Temperature range:

 

- 20... + 60°C

 

(at range 0 ... - 20°C limited

 

function of the LCD display)

Clearance and creepage distance
rated impulse voltage /
pollution degree:

 

4 kV / 2     

high voltage test:

 

IEC/EN 60 664-1

EMC

Electrostatic discharge (ESD):  8 kV (air) 

IEC/EN 61 000-4-2

Fast transients: 

2 kV 

IEC/EN 61 000-4-4

Surge voltage:  

5 kV / 0.5J 

IEC/EN 61 000-4-5

HF-wire guided: 

10 V 

IEC/EN 61 000-4-6 

Interference suppression: 

Limit value class A 

EN 61 000-6-4

Degree of protection

Housing: 

IP 40 

DIN EN 60 529

Terminals:  

IP 20 

DIN EN 60 529

Housing: 

 

thermoplastic with VO behaviour

 

according to UL Subject 94

Vibration resistance:

 

Amplitude 0.35 mm, 

 

frequency 10 ... 55 Hz

Climate resistance: 

 

20 / 060 / 04 

EN 60 068-1

Wire connection

 

 

   

  DIN 46 228-1/-2/-3/-4

Screw terminal
(fixed):

 

1 x 4 mm

2

 solid or

   

1 x 2.5 mm

2

 stranded ferruled (isolated) or

   

2 x 1.5 mm

2

 stranded ferruled (isolated) or 

   

2 x 2.5 mm

2

 solid

Insulation of wires or 
sleeve length: 

8 mm

Terminal block
with screw terminals

Max. cross section: 

1 x 2.5 mm

2

 solid or

   

1 x 2.5 mm

2

 stranded ferruled (isolated)

Insulation of wires or 
sleeve length: 

8 mm 

Terminal block
with cage clamp terminals

Max. cross section: 

1 x 4 mm

2

 solid or

   

1 x 2.5 mm

2

 stranded ferruled (isolated)

Min. cross section: 

0.5 mm

2

Insulation of wires or 
sleeve length: 

12 

+0.5 

mm

Wire fixing:

 

Plus-minus terminal screws M3,5 box 

   

terminals with wire protection

   

or cage clamp terminals

Mounting:

 

DIN rail  

EN 60 715

Weight:

 

MK 9300N: 

approx.  140 g

MH 9300: 

approx.  250 g

Dimensions

Width x height x depth:

 

MK 9300N: 

22.5 x 90 x 97 mm

MH 9300: 

   45 x 90 x 97 mm

  Ordering Example

MK 9300N  .11  _ _  /022  3 AC 20 ... 440 V   AC 12 A   DC 24 V 
 

 

   

 

Auxiliary voltage U

H

 

Measuring current U

M

  

 

 

   

 Measuring voltage

 

Type of terminals

 

  without indication: 

 

   terminal blocks fixed

 

    with screw terminals

 

PC (plug in cage clamp): 

 

 pluggable terminal blocks 

 

  with cage clamp terminals

 

PS (plug in screw): 

 

  pluggable terminal blocks 

 

  with screw terminals

 Contacts
 Type

 

Notes

Removing the terminal blocks with cage clamp terminals

1.  The unit has to be disconnected.
2.  Insert a screwdriver in the side recess of the front plate.
3.  Turn the screwdriver to the right and left.
4.  Please note that the terminal blocks have to be mounted on the
  belonging plug in terminations.

 

Options with Pluggable Terminal Blocks

Screw terminal

(PS/plugin screw)

Cage clamp terminal

(PC/plugin cage clamp)

Содержание VARIMETER PRO

Страница 1: ...ng of portable equipment Motor protection on Phase failure Transformer protection on asymmetric load Frequency monitoring on inverter outputs 0268581 More Information MK 9300N The MK9300N has 1 relay...

Страница 2: ...RUN mode and continuously measures the actual values The buttons and toggle between the different values Pressing Esc for more than 3 sec starts the input mode One or more measuring values can be ass...

Страница 3: ...mode Scrolls the display to show one of the 10 possible values If a values exceeds the setting the values is indicated flashing on inverted display In the case of a fault display the display always r...

Страница 4: ...t changes to input mode In input mode the measurement is disabled the relays are in failure mode and the indicator LED is orange With the buttons the different setting values can be chosen Move cursor...

Страница 5: ...A Umin V tv 1 A R Pheq Sp 1 Umin V Umax V Umin V tv 1 A R Pheq Sp 1 R1 R1 R1 R1 R2 R2 R2 R2 Esc Esc Esc Esc Esc Esc Esc Esc Esc Esc actual value actual value actual value actual value actual value act...

Страница 6: ...rating Setting valid for both relays Start up delay ta 0 10 s in steps of 0 1 s Current Measuring Input i k Nominal current AC 12 A Measuring range AC 100 mA 12 A Max overload continuously 16 A short...

Страница 7: ...IN EN 60 529 Terminals IP 20 DIN EN 60 529 Housing thermoplastic with VO behaviour according to UL Subject 94 Vibration resistance Amplitude 0 35 mm frequency 10 55 Hz Climate resistance 20 060 04 EN...

Страница 8: ...s voltage Electric shock will result in death or serious injury Disconnect all power supplies before servicing equipment Faults must only be removed when the relay is disconnected The user has to make...

Отзывы: