UnLock_cmd input
LockOut output
ErrorOut putput
Output output
The “Unlock_cmd” input detects the command sent by the user to lock or unlock the guard lock.
In detail:
- Request to unlock: the Unlock_cmd signal must be set to LL1
- Request to lock: the Unlock_cmd signal must be set to LL0
The command signal may be sent via a key, for example
This signal controls the guard lock electromagnet and can assume LL0 and LL1 value.
If enabled, when this signal is set to LL1 it indicates an error in the control of the guard lock. It is set to LL0 when
no errors have occurred.
This signal indicates the information shown in the table below, depending on its value.
Value
MEANING
Output
LL1
- Door / Gate closed
- Guard lock locked
Output
LL0
- User request to unlock the guard lock
- Error condition