27
BH 5910 / 200217 / 190A
Light curtains
and E-stop
Pic. 7: Light curtains and E-stop, auto start or manual start (switch 1 in position 2, switch 10 in position 0 or 1)
Light curtains and E-stop, auto start
Light curtains and E-stop, manual start
Auxiliary voltage (A1/A2)
LC
E-stop
Start button (S43/S44)
K1/K2 (13-14, 23-24, 33-34)
Output 48 (failure state)
Output 58 (waiting for start)
: off
: on
: flashing
M8434
Auxiliary voltage
(A1/A2)
LC
E-stop
Start button (S43/S44)
K1/K2 (13-14,
23-24, 33-34)
Output 48
(failure state)
Output 58
(waiting for start)
: offl
: on
: flashing
M8435
L+
L -
M8436_a
BH5910
K1
K2
13
23
33
34
24
14
48
58
A2-
A1+
start
S11 S12 S14 S13
S21 S22 S24 S23
S31 S32 S34 S33
S41 S42 S44 S43
E-
stop
LC 1
LC 2
trans-
mitter
trans-
mitter
waiting for start
failure state
machine enabling