46
Dolby
®
CP750 Digital Cinema Processor Manual
Aligning the Auditorium
Figure
6
‐
2
Figure 6-2
Alignment Tab Showing Room Levels
6.4
Calibrating the Internal SPL Meter
You
must
calibrate
the
internal
SPL
before
proceeding
with
alignment.
1.
To
start
the
process,
click
C
under
Signal
Generator
Enable
to
activate
the
Center
channel.
2.
Select
Pink
Noise
from
the
Signal
Mode
drop
‐
down
list.
Pink
noise
is
sent
to
the
Center
channel
speaker.
3.
Check
the
microphone
level
to
be
sure
it
appears
in
the
target
range
as
shown
in
If
necessary,
adjust
the
Mic. Gain
on
the
rear
panel
of
the
CP750
until
the
level
is
within
the
target
range.
Note:
The
CP750
is
shipped
from
the
factory
with
the
Mic.
Input
level
control
set
to
the
minimum.