Connecting to a Local or Remote Device
Dolby
®
CP750 Digital Cinema Processor Manual
19
Figure
3
‐
3
Figure 3-3
Action Menu
These
options
allow
you
to
connect
to
a
CP750
that
is
either
connected
to
your
PC
(local
device)
or
connected
to
an
Ethernet
network
(remote
device).
If
you
select
Connect
to
remote
device
,
the
system
prompts
you
to
enter
an
IP
address.
You
must
change
TCP/IP
properties
of
your
laptop
to
communicate
properly
with
the
CP750
when
connecting
the
setup
software
to
a
CP750
using
a
PC
Ethernet
connection.
We
recommend
the
following
TCP/IP
settings
to
enable
your
PC
to
communicate
with
a
CP750
using
its
default
setting.
IP
address:
192.168.1.200
Subnet
mask:
255.255.255.128
Default
gateway:
192.168.1.129
Note:
The
CP750
default
IP
address
(for
connecting)
is
192.168.1.136.