24
999817902 - 10/2022
Scaffold
User Information
Ringlock
Attachment point for personal fall-
arrest set
The following guidelines are provided to help you select
the most appropriate locations for attaching a harness
to Ringlock scaffolding.
The guidelines presented in this document do not
replace established Health and Safety guidelines.
Refer to the Work at Height Regulations and Safety
Guidance Notes provided by the NASC where neces-
sary.
▪
The rosette on a Standard is a proper connection
point for the Scaffold Hook attached to a Lanyard.
The Standard must be continuous to the base plate.
No more than one person per 2.0 m (6'-6") lift can be
attached to a single Standard.
Ringlock Rosette
▪
It is recommended to connect the Scaffold Hook to
the large trapezoidal holes to provide a suitable
anchor point for the appropriate safety harness.
▪
DO NOT attach the safety harness lanyard to itself
around a Standard because the edge of the rosette
may cut the fabric or it may slip over the rosette to the
next lower rosette increasing the fall distance.
Connection to a Standard
To ensure a positive connection is created it is recom-
mended that joints between Standards are pinned
together (ensure site/local regulations and current Leg-
islation are followed). A scaffolder can connect to any
rosette up to the third rosette above the Ledgers.