background image

5

Check alignment of pillow block by noting clearance between 
housing and shaft at each end of the housing. Clearance should 
be uniform within 1/32”. Shim bearing pedestal where possible; 
otherwise, use full length shims under base as required. 
Alignment of pillow block should be accurate to prevent the seals 
from rubbing.

Tighten the four pedestal bolts to torque value given in Table 3. 
Shaft should rotate freely. 

INSTALLATION OF OIL SEALS

Cut the O-ring (rubber cord) and wrap it around the shaft inside 

the seal groove. If the O-ring is too large, cut it to fit the shaft. 

For most effective sealing, ends of O-ring must meet. Cement or 
glue the ends together. Lubricate O-ring with oil or grease.

Apply a thin coat of heavy oil or light grease in the housing seal 
grooves to extend seal life.

Disassemble one seal and place one half on shaft with flinger 
facing liner. Locate O-ring in seal groove and rotate seal half 
around shaft into housing base groove.

Install other half of seal and tighten screws to torque given in 
Table 3. Check to make sure the seal will slide along the shaft 
with minimum effort to allow for shaft expansion. Align the seal in 
the middle of the seal groove.

Install second seal in same manner. If end closure is to be used, 
the neoprene disc is to be installed on one end at this time 
instead of the bearing seal. Consult construction drawing. 

Table 3

RTL SLEEVOIL 

SIZE

 

HOUSING/PEDESTAL BOLTS

 SEAL CLAMP SCREWS

THREAD 

 SIZE 

TORQUE 

(IN.-LBS.) 

THREAD 

SIZE 

TORQUE 

(IN.-LBS.) 

3-7/16 

3-15/16 

3/4 

7/8 

2100 

2040 

10–24 

10–24 

12 

12 

4-7/16 

4-15/16 

3000 

3000 

10–24

10–24 

12 

12 

5-7/16 

1-

1/8

1-1/4 

4200 

6000 

1/4–20 

1/4–20 

33 

33 

1-1/2 

1-3/4 

10000 

11500 

5/16–18 

5/16–18 

65

 65 

10 

12 

1-3/4 

11500 

15000

15000 

3/8–16 

3/8–16 

3/8–16 

120 

120 

120 

INSTALLATION OF HOUSING CAP

Back off the plunger screw as far as possible.

Along the outer contour of the housing base, apply the supplied 
LOCTITE

® 

515 or an equivalent sealant to the joint. CAREFULLY 

place the housing cap on the base, and take special precautions 
to prevent seal damage.

The plunger screw must remain loose until the housing bolts 
have been tightened.

Содержание SLEEVOIL RTL 10

Страница 1: ...y qualified personnel who are familiar with the construction and operation of all equipment in the system and the potential hazards involved When risk to persons or property may be involved a holding...

Страница 2: ...les in the liner are aligned with the two thermocouple RTD holes in the housing Apply oil to the liner bearing surface NOTE Liner has been machined to close tolerances Scraping of bore is not necessar...

Страница 3: ...ty of the liner base INSTALLATION OF OIL RINGS NOTE Do NOT use oil rings if liner cap has baffles installed in the oil ring grooves Oil rings are shipped disassembled with two extra screws Place oil r...

Страница 4: ...NG If it ever becomes necessary to remove liner cap make certain that both upper thrust plate halves remain in place next to the thrust collar If a plate half should remain in the liner cap it can dro...

Страница 5: ...l other half of seal and tighten screws to torque given in Table 3 Check to make sure the seal will slide along the shaft with minimum effort to allow for shaft expansion Align the seal in the middle...

Страница 6: ...position of the plunger screw Loosen plunger screw one turn and loosen shaft hold down Next tighten plunger screw to the mark Remove shaft hold down and tighten plunger screw locknut NOTE Do NOT tigh...

Страница 7: ...e the probe tips contact the end of the drilled holes in the liner Use sealant on all threaded connections Check construction drawings to determine if coolant water or air is to be supplied to the bea...

Страница 8: ...cosity is determined by the equipment manufacturer and normally specified on the construction drawing Information regarding qualities and properties of specific oils should be referred to the lubrican...

Страница 9: ...temperatures can be as harmful to the bearing as high temperatures The Dodge heater thermostat combo can be used in these low ambient conditions The Dodge heater thermostat combo turns on at 70 F and...

Страница 10: ...135290 135291 135292 135293 135294 135295 135296 135297 135298 135299 135135 36 38 RTL Seal Kit Clamp Seal Assembly O Ring 2 2 2 435001 435002 435003 435004 435005 435006 435007 435008 435009 435010...

Страница 11: ...ld cuttable stainless steel probe a platinum sensing element and a spring loaded fitting with an oil seal COOL LUBE 2 All the features of the OLF 2 system plus a built in heat exchanger for continuous...

Страница 12: ...Dodge Industrial Inc 1061 Holland Road Simpsonville SC 29681 1 864 297 4800 All Rights Reserved Printed in USA MN3060 02 22 3060 0222 DODGE INDUSTRIAL INC AN RBC BEARINGS COMPANY...

Отзывы: