8-8-2006
Handleiding
EN STF V1.0
www.doco-international.com
4
2.2 Guarantee and liability
Unprofessional assembly, any changes made to the garage door or changes in the door operator that do not
comply with this manual will annul the guarantee and liability.
This also applies to damage caused by incorrect operation, failure to observe the instructions in this manual
and/or poor maintenance or care.
3. Directives, applications and limitations
Doco garage doors comply with the following Directives:
•
EMC Directive*
•
LVD Directive*
•
Machine Directive*
•
CPD Directive*
(* E driven doors).
DOCO International developed this hardware set, which is intended for mounting in residential garages:
•
Max. width 5000 mm
•
Max height 2580 mm
•
Weight door panel: max 162 kg
•
Noise production: : <70 dBa
•
Temperature range: –20º to + 40ºC
•
Service-life 25,000 cycles
•
CE approved according to SP certificate for use with the correct DOCO parts (see parts lists SET 1 to 4)
DOCO International had the “Product Test“ (ITT Initial Type testing) of this set of fittings carried out by the
institute SP in Sweden, known as Notified Body No. 0402.
Documents of this “ITT” are available from DOCO upon request.
The person or the company installing this door must thoroughly check if the door can be operated safely in
combination with the selected E-drive and panel, see “Product test report (ITT Report)”; Annex A and B.
This “ITT” does NOT include a pass door. If you want to install a pass door, a separate Product Test must be
carried out. This is the responsibility of the garage door manufacturer.
If parts are mounted that are not mentioned or if other parts are used that are not listed in this manual, the CE
certification will be invalid!